【24h】

Anatomy of subaxial cervical foramens: the safety zone for lateral mass screwing.

机译:颈下椎间孔的解剖:侧块螺钉固定的安全区。

获取原文
获取原文并翻译 | 示例
           

摘要

INTRODUCTION: The purpose of this study was to measure the structures of the ventral of lateral masses using cadaver specimens and to quantitatively compare the safety zone for the two major techniques used on each vertebral level from C3 to C6. METHODS: This study is based on 52 cervical vertebrae of 13 cadavers. The anatomical measurements focused on the anterior surface of the lateral mass. We investigated the safety width, heights, and the height of nerve roots. RESULTS: The mean values of the safety width of the Magerl technique from C3 to C6 were 6.1, 7.3, 6.4 and 4.3 mm, respectively. The mean values of the safety width of the Roy-Camille technique were 6.7, 6.6, 5.8 and 5.4 mm, respectively. The mean values of the safety height of the Magerl technique were 5.0, 5.4, 5.8 and 5.2 mm, respectively. The mean values of the safety height of the Roy-Camille technique were 4.9, 4.0, 1.0 and -1.2 mm, respectively. The mean values of the nerve root height were 3.9, 4.9, 5.9 and 6.9 mm, respectively. CONCLUSION: The safety width of the Magerl technique was shorter at C6 because the vertebral artery runs more laterally at C6. The height for the Magerl technique was not significantly different from C3 to C6, however, the safety height for the Roy-Camille technique was significantly shorter at C5 and C6. Our findings suggest that it is important to ensure that the screw(s) penetrate through the cranial side of the ventral aspect of a lateral mass when performing the Magerl technique at all vertebral levels, and to carefully select the screw length when using the Roy-Camille technique, especially at C5 and C6, in order to avoid nerve root injury.
机译:简介:本研究的目的是使用尸体标本测量侧块腹侧的结构,并定量比较从C3到C6在每个椎骨水平上使用的两种主要技术的安全区。方法:本研究基于13具尸体的52个颈椎。解剖学测量集中在侧块的前表面。我们调查了安全宽度,高度和神经根的高度。结果:Magerl技术从C3到C6的安全宽度的平均值分别为6.1、7.3、6.4和4.3 mm。 Roy-Camille技术的安全宽度的平均值分别为6.7、6.6、5.8和5.4毫米。 Magerl技术的安全高度的平均值分别为5.0、5.4、5.8和5.2 mm。 Roy-Camille技术的安全高度的平均值分别为4.9、4.0、1.0和-1.2毫米。神经根高度的平均值分别为3.9、4.9、5.9和6.9 mm。结论:Magerl技术的安全宽度在C6处更短,因为椎动脉在C6处更侧行。 Magerl技术的高度从C3到C6并无显着差异,但是Roy-Camille技术的安全高度在C5和C6处明显短。我们的发现表明,在所有椎骨水平上进行Magerl技术时,确保螺钉穿过侧块腹侧的颅侧很重要,并在使用Roy-卡米尔技术,特别是在C5和C6处,以避免神经根损伤。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号