OBJECTIVE: A new device for performing quick sutureless vascular anastomosis by means of stent technology has recently been developed by Jomed International, Helsingborg, Sweden. The efficacy of this GraftConnector was studied in a sheep model. METHODS: In adult sheep, a left anterior thoracotomy under the fourth rib extended across the sternum gave good access to the left anterior descending branch (LAD) and the right internal mammary artery (RIMA). On beating hearts, the GraftConnector group had the RIMA connected to the LAD by means of the new device, while the control animals had the same anastomoses sutured with continuous 7-0 polypropylene sutures. The time for completing the anastomosis (ischemic time) was recorded and the blood flow in the RIMA was recorded with the proximal LAD open and closed, respectively. An intra-operative fluoroscopy with contrast injection directly into the graft was done. Finally the proximal LAD was ligated. The surviving animals are to be followed up. RESULTS: Seven (46%) of the 15 animals operated on with the traditional suturing technique and seven (63%) of the 11 GraftConnector sheep survived the procedures and are to be followed up. The 11 anastomoses done with the GraftConnector were completed in 2.41+/-0.2 min, and the 14 anastomoses sutured with continuous suture were completed in 6.93+/-0.419 min (P<0.0001). The RIMA blood-flows in the two groups were comparable and are presented. All the surviving animals had open anastomoses at fluoroscopy. CONCLUSIONS: Quick coronary artery anastomoses without suturing on beating hearts can be completed with the new GraftConnector. The GraftConnector creates reproducible anastomoses in much less time than suturing, the per-operative mortality in the GraftConnector Group was accordingly lower. Long-time follow-up of the patency in surviving animals is pending. The presented device may ultimately permit quick anastomoses endoscopically.
机译:目的:最近由瑞典赫尔辛堡的Jomed International开发了一种通过支架技术进行快速无缝合血管吻合术的新设备。在绵羊模型中研究了此GraftConnector的功效。方法:在成年绵羊中,第四肋骨下方延伸穿过胸骨的左前胸廓开孔使左前降支(LAD)和右乳内动脉(RIMA)进入良好。在跳动的心脏上,GraftConnector组通过新设备将RIMA连接到LAD,而对照组动物则用连续的7-0聚丙烯缝合线缝合了相同的吻合口。记录完成吻合的时间(缺血时间),并记录近端LAD打开和关闭时RIMA中的血流量。术中用造影剂直接注入移植物中进行了透视检查。最后,结扎近端LAD。幸存的动物将被跟进。结果:15只动物中有7只(46%)采用传统的缝合技术进行手术,而11只GraftConnector绵羊中有7只(63%)在手术后幸存下来,需要进行随访。用GraftConnector完成的11个吻合在2.41 +/- 0.2分钟内完成,用连续缝合缝合的14个吻合在6.93 +/- 0.419分钟内完成(P <0.0001)。两组的RIMA血流具有可比性,并进行了介绍。所有存活的动物在荧光检查中均具有开放的吻合口。结论:新的GraftConnector可以完成快速的冠状动脉吻合而不缝合跳动的心脏。与缝合相比,GraftConnector产生的吻合时间要短得多,因此,GraftConnector组的平均手术死亡率更低。存活动物的通畅性的长期随访仍在进行中。所提出的装置可以最终允许内窥镜快速吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号