Editor's choice - Use of disposable radiation-absorbing surgical drapes results in significant dose reduction during EVAR procedures

机译:编辑选择-使用一次性吸收辐射的手术单可大大减少EVAR手术期间的剂量

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives Because of the increasing number of interventional endovascular procedures with fluoroscopy and the corresponding high annual dose for interventionalists, additional dose-protecting measures are desirable. The purpose of this study was to evaluate the effect of disposable radiation-absorbing surgical drapes in reducing scatter radiation exposure for interventionalists and supporting staff during an endovascular aneurysm repair (EVAR) procedure. Materials This was a randomized control trial in which 36 EVAR procedures were randomized between execution with and without disposable radiation-absorbing surgical drapes (Radpad: Worldwide Innovations & Technologies, Inc., Kansas City, US, type 5511A). Dosimetric measurements were performed on the interventionalist (hand and chest) and theatre nurse (chest) with and without the use of the drapes to obtain the dose reduction and effect on the annual dose caused by the drapes. Results Use of disposable radiation-absorbing surgical drapes resulted in dose reductions of 49%, 55%, and 48%, respectively, measured on the hand and chest of the interventionalist and the chest of the theatre nurse. Conclusions The use of disposable radiation-absorbing surgical drapes significantly reduces scatter radiation exposure for both the interventionalist and the supporting staff during EVAR procedures.
机译:目的由于使用透视检查法进行介入性血管内手术的数量不断增加,并且介入者的相应年剂量较高,因此需要采取其他剂量保护措施。这项研究的目的是评估介入治疗人员和支持人员在血管内动脉瘤修复(EVAR)程序中使用的一次性吸收辐射的手术单在减少散射辐射暴露方面的效果。材料这是一项随机对照试验,其中在使用和不使用一次性吸收辐射的手术单(Radpad:Worldwide Innovations&Technologies,Inc.,美国堪萨斯城,美国,类型5511A)之间,随机执行36个EVAR程序。在介入人员(手和胸部)和剧院护士(胸部)上进行剂量测定,无论是否使用窗帘,以减少剂量并影响窗帘的年剂量。结果使用一次性吸收辐射的手术单可减少干预人员的手和胸部以及剧院护士的胸部的剂量,分别降低49%,55%和48%。结论在EVAR手术过程中,使用一次性吸收辐射的手术单可显着减少干预人员和支持人员的散射辐射。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号