Aims: We evaluated the accuracy of three-dimensional speckle-tracking echocardiography (3DSTE) to evaluate left ventricular (LV) volumes, ejection fraction (EF), and global circumferential strain (CS) in comparison with cardiac magnetic resonance imaging (MRI) in a healthy population. Methods and results: A total of 45 out of 50 consecutive healthy subjects (38 males, age 45 ± 15 years) successfully underwent both 3DSTE and MRI on the same day. Three-dimensional echocardiography data sets were analysed using speckle tracking to measure LV end-diastolic and end-systolic volumes, EF, and global CS. With MRI, the method of discs approximation was used to obtain volumes and the EF, whereas CS was acquired using myocardial tissue tagging. Inter-technique comparisons included regression and the Bland-Altman analysis. For quantification of LV volumes, 3DSTE correlated well with MRI (r: 0.75-0.81), but volumes were significantly underestimated with relatively large biases (13-34 mL) and wide limits of agreement (SD: 11-25 mL). However, excellent accuracy was revealed for measurement of EF by 3DSTE with a good correlation (r: 0.91), minimal bias, and narrow limits of agreement (0.6 ± 1.7) compared with MRI. For measurement of CS, a large mean bias was found between techniques (10.0), despite narrow limits of agreement (SD: 1.7) and a good correlation between techniques (r: 0.80). Conclusion: Although 3DSTE-derived LV volumes are underestimated in most patients compared with MRI, measurement of the LVEF revealed excellent accuracy. Measurements of CS were systematically greater (i.e. more negative) with 3DSTE than MRI, which likely reflects various inter-technique differences that preclude direct comparability of their measurements.
机译:目的:我们评估了三维散斑跟踪超声心动图(3DSTE)的准确性,以评估左心室(LV)体积,射血分数(EF)和整体圆周应变(CS)与心脏磁共振成像(MRI)的比较。健康的人群。方法和结果:连续50例健康受试者中的45例(男性38例,年龄45±15岁)在同一天成功接受了3DSTE和MRI检查。使用斑点追踪分析了三维超声心动图数据集,以测量左室舒张末期和收缩末期容积,EF和整体CS。对于MRI,使用椎间盘近似法获得体积和EF,而使用心肌组织标记法获得CS。技术间的比较包括回归和Bland-Altman分析。为了量化左室容积,3DSTE与MRI的相关性很好(r:0.75-0.81),但是由于相对较大的偏倚(13-34 mL)和较宽的一致限度(SD:11-25 mL),容积明显被低估了。然而,与MRI相比,通过3DSTE测量EF表现出极好的准确性,具有良好的相关性(r:0.91),最小的偏差和一致的限制(0.6±1.7)。对于CS的测量,尽管协议范围狭窄(SD:1.7),并且技术之间的相关性很好(r:0.80),但在技术之间发现了较大的平均偏差(10.0)。结论:尽管与MRI相比,大多数患者低估了3DSTE衍生的LV量,但LVEF的测量显示出极好的准确性。使用3DSTE进行的CS测量在系统上要比MRI更大(即更阴性),这很可能反映了各种技术间的差异,从而无法直接比较它们的测量结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号