首页> 外文期刊>Engineering failure analysis >Failure analysis of the brass tubes in a lubricating oil cooler
【24h】

Failure analysis of the brass tubes in a lubricating oil cooler

机译:润滑油冷却器中黄铜管的故障分析

获取原文
获取原文并翻译 | 示例
           

摘要

Failure analysis was carried out on leaked brass tubes of a lubricating oil cooler. Direct evidences of dezincification and stress corrosion cracking (SCC) were observed by scanning electron microscope (SEM) and energy dispersive spectroscopic (EDS) analysis. It is found that there are many small pits distributed on the fracture surface and EDS analysis revealed the occurrence of dezincification in the small pits. SCC was observed on the cross-sectional plane of the fracture by SEM. Ammonia test has proved the existence of residual stress in the as-received tubes. It is determined that the brass tubes have been suffered from the co-action between dezincification and SCC.
机译:对润滑油冷却器泄漏的黄铜管进行了故障分析。通过扫描电子显微镜(SEM)和能量色散光谱(EDS)分析观察到了脱锌和应力腐蚀开裂(SCC)的直接证据。发现裂缝表面分布着许多小凹坑,EDS分析表明小凹坑中发生了脱锌现象。通过SEM在断裂的横截面上观察到SCC。氨气测试证明了在收到的管中存在残余应力。可以确定黄铜管受到脱锌和SCC之间相互作用的影响。