Root Cause Analysis of Tube Weld Failure of the Lubrication Oil Cooling Tube in Thrust Bearing of Pump

机译:泵推力轴承润滑油冷却管焊接失效的根本原因分析。

获取原文
获取原文并翻译 | 示例

摘要

Dissimilar weld region located at the cooling tube of pump was damaged and failed. We performed a root cause analysis using the Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Spectroscopy for the fractured surface. Many internal defects were shown in the fracture section. Root cause analysis shows that the failure is due to welding at higher temperature over 1000℃. This was confirmed by high-temperature cracks observed with SEM. In this study Failure scenario including initial crack generation, propagation of corrosion cracks and final failure, has been constructed and verified.
机译:位于泵冷却管上的不同焊接区域损坏并发生故障。我们使用扫描电子显微镜(SEM)和能量色散X射线光谱仪对断裂的表面进行了根本原因分析。断裂部位显示出许多内部缺陷。根本原因分析表明,故障是由于在1000℃以上的高温下焊接造成的。通过SEM观察到的高温裂纹证实了这一点。在本研究中,已经构建并验证了包括初始裂纹生成,腐蚀裂纹扩展和最终失效在内的失效场景。