首页> 外文期刊>Engineering failure analysis >Failure of refurbished turbine blades in a power station by improper heat treatment
【24h】

Failure of refurbished turbine blades in a power station by improper heat treatment

机译:热处理不当会导致电厂翻新的涡轮叶片失效

获取原文
获取原文并翻译 | 示例
           

摘要

Turbine blades in a power station exposed to a temperature of about 800 deg were refurbished after 40,000 h of operation. However, after only 900 h of service at the same temperature, a number of refurbished blades were fractured. Various electron microscopy techniques as well as computational modeling were used to develop a one-to-one correspondence between microstructure and temperature distribution. Fracture was found to occur by a ductile intergranular mode. Although there was no evidence for overheating during service, the results showed that the blades initially contained gamma min precipitate-free zones alongside grain boundaries, which could accelerate intergranular failure consistent with the observed fracture mode. It was concluded that the blades were damaged by improper heat treatment during refurbishing.
机译:在运行40,000小时后,对暴露于约800度温度的电站中的涡轮叶片进行翻新。但是,在相同温度下仅服务900小时后,许多翻新的刀片断裂。各种电子显微镜技术以及计算模型被用来开发微观结构和温度分布之间的一对一对应关系。发现断裂是由韧性晶间模式发生的。尽管没有证据表明在使用过程中会出现过热现象,但结果表明,叶片最初在晶界旁边包含无γmin的无沉淀区,可加速晶粒间破坏,与观察到的断裂模式一致。结论是,翻新过程中热处理不当会损坏刀片。