首页> 外文期刊>Electroanalysis >Flow injection chemiluminescence determination of captopril with in situ electrogenerated Mn3+ as the oxidant
【24h】

Flow injection chemiluminescence determination of captopril with in situ electrogenerated Mn3+ as the oxidant

机译:原位电生成的Mn3 +作为氧化剂流动注射化学发光法测定卡托普利

获取原文
获取原文并翻译 | 示例

摘要

By designing a novel flow-through electrolytic cell, a new flow-injection electrogenerated chemiluminescence method for the determination of captopril is described. It is based on the direct chemiluminescence oxidation of captopril by nascent Mn3+ which was in situ electrogenerated on the near surface of the platinum flake electrode by electrochemical oxidizing MnSO4 in sulfuric acid medium. The proposed procedure has a linear application range of 3.0 x 10(-7)-1.0 x 10(-4) mol/L for captopril (r=0.9998) and with a detection limit of 8.0 x 10(-8) mol/L original concentration. Designing of the flow-through electrolytic cell as well as some experimental conditions for the determination of captopril are optimized and the possible reaction mechanism is also discussed. The method was successfully used for the determination of captopril in a pharmaceutical preparation. [References: 36]
机译:通过设计一种新颖的流通式电解槽,描述了一种测定卡托普利的新的流动注射电生化学发光方法。它基于新生的Mn3 +对卡托普利的直接化学发光氧化,而Mn3 +是在硫酸介质中通过电化学氧化MnSO4在铂片状电极的近表面上原位电生成的。拟议的程序对卡托普利的线性应用范围为3.0 x 10(-7)-1.0 x 10(-4)mol / L(r = 0.9998),检出限为8.0 x 10(-8)mol / L原始浓度。优化了流通式电解池的设计以及测定卡托普利的一些实验条件,并讨论了可能的反应机理。该方法已成功用于药物制剂中卡托普利的测定。 [参考:36]