...
首页> 外文期刊>Electromyography and Clinical Neurophysiology: International Bimonthly Review >The effects of parallel versus perpendicular electrode orientations on EMG amplitude and mean power frequency from the biceps brachii.
【24h】

The effects of parallel versus perpendicular electrode orientations on EMG amplitude and mean power frequency from the biceps brachii.

机译:平行与垂直电极方向对肱二头肌肌电幅度和平均功率频率的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

The purposes of this study were threefold: (1) to compare the isometric torque-related patterns of absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) responses for electrode orientations that were parallel and perpendicular to the muscle fibers; (2) to examine the influence of electrode orientation on mean absolute EMG amplitude and MPF values; and (3) to determine the effects of normalization on mean EMG amplitude and MPF values from parallel and perpendicular electrode orientations. Ten adults (5 men and 5 women mean +/- SD age = 23.8 +/- 2.3 years) volunteered to participate in the investigation. Two sets of bipolar surface EMG electrodes (20 mm center to center) were placed parallel and perpendicular to the muscle fibers over the biceps brachii. The subjects performed a maximal voluntary isometric contraction (MVIC) test followed by randomly ordered submaximal muscle actions in 10% increments from 10 to 90% MVIC. Paired t-tests indicated that absolute EMG amplitude values for the parallel electrode orientation were greater (p < 0.05) than those for the perpendicular orientation at all isometric torque levels except 10% MVIC For normalized EMG amplitude values, however, there were no significant mean differences between electrode orientations. There were also no differences between electrode orientations for absolute or normalized EMG MPF values. In 30% of the cases, different torque-related patterns of responses were observed between the parallel and perpendicular electrode orientations for the absolute and normalized EMG amplitude and MPF values. Therefore, the results of the present study support the need for standardizing electrode orientation to compare the pattern of responses for EMG amplitude and MPF values and normalizing EMG amplitude data to compare the mean values.
机译:这项研究的目的有三方面:(1)比较与平行和垂直于肌纤维的电极方向的绝对和归一化肌电图(EMG)振幅和平均功率频率(MPF)响应的等轴测扭矩相关模式; (2)检查电极取向对平均绝对EMG振幅和MPF值的影响; (3)从平行和垂直电极方向确定归一化对平均EMG幅度和MPF值的影响。十名成人(5名男性和5名女性平均+/- SD年龄= 23.8 +/- 2.3岁)自愿参加了调查。两组双极表面肌电图电极(中心距中心20 mm)平行放置并垂直于肱二头肌上方的肌纤维。受试者进行了最大自愿等距收缩(MVIC)测试,然后以10%至90%MVIC的10%增量随机排序次最大肌肉动作。配对t检验表明,在所有等距转矩水平下,平行电极方向的绝对EMG振幅值均大于(p <0.05)垂直方向的绝对值,但MVIC除外对于标准化的EMG振幅值,均无显着平均值电极方向之间的差异。绝对或标准化EMG MPF值的电极方向之间也没有差异。在30%的情况下,对于绝对和标准化的EMG振幅和MPF值,在平行和垂直电极方向之间观察到不同的转矩相关响应模式。因此,本研究的结果支持对标准化电极方向以比较EMG振幅和MPF值的响应模式以及对EMG振幅数据进行标准化以比较平均值的需求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号