首页> 外文期刊>Journal of electromyography and kinesiology: Official journal of the International Society of Electrophysiological Kinesiology >The effects of electrode placement and innervation zone location on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis muscle
【24h】

The effects of electrode placement and innervation zone location on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis muscle

机译:电极位置和神经支配区域位置对股外侧肌的肌电幅度和平均功率频率与等距扭矩关系的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The purposes of this investigation were to examine the effects of electrode placement and innervation zone (IZ) location on: (a) the torque-related patterns of responses for absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) and (b) the mean absolute and normalized EMG amplitude and MPF values. In addition, the present study examined the variability between subjects for the location of the IZ for the vastus lateralis (VL). Eight men (mean +/- SD age = 23.0 +/- 4.3 yr) performed submaximal to maximal isometric muscle actions of the dominant leg extensors. During each muscle action, fifteen channels of bipolar surface EMG signals were detected from the vastus lateralis using a linear electrode array aligned with the long axis of the muscle fibers. The results indicated that there were differences among channels 1-15 for the patterns of responses and mean values for absolute and normalized EMG amplitude and MPF versus isometric torque. Thus, normalized EMG amplitude and MPF values from different individuals cannot be compared if the EMG signals were detected from different locations over the muscle. In addition, absolute and relative (to femur length) estimates of IZ location for the VL resulted in similar inter-subject variability. (C) 2006 Elsevier Ltd. All rights reserved.
机译:这项研究的目的是检查电极放置和神经支配区(IZ)位置对以下方面的影响:(a)绝对和归一化肌电图(EMG)振幅和平均功率频率(MPF)的与转矩相关的响应模式,以及( b)绝对和标准化的平均EMG振幅和MPF值。此外,本研究检查了受试者之间的外侧阔肌(VL)IZ位置的变异性。八名男子(平均+/- SD年龄= 23.0 +/- 4.3岁)进行了次要的至最大的支腿伸肌等长肌动作。在每次肌肉动作期间,使用与肌肉纤维的长轴对齐的线性电极阵列从股外侧肌中检测到15个双极表面EMG信号通道。结果表明,通道1-15之间的响应模式和绝对和标准化EMG振幅以及MPF与等距转矩的平均值之间存在差异。因此,如果从肌肉上的不同位置检测到EMG信号,则无法比较来自不同个体的标准化EMG振幅和MPF值。此外,VL的IZ位置的绝对和相对(相对于股骨长度)估计值导致相似的受试者间变异性。 (C)2006 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号