首页> 外文期刊>Earth, planets and space: EPS >Development of low-cost sky-scanning Fabry-Perot interferometers for airglow and auroral studies
【24h】

Development of low-cost sky-scanning Fabry-Perot interferometers for airglow and auroral studies

机译:研发用于气辉和极光研究的低成本天空扫描法布里-珀罗干涉仪

获取原文
获取原文并翻译 | 示例
           

摘要

We have developed new Fabry-Perot interferometers (FPIs) that are designed to measure thermospheric winds and temperatures as well as mesospheric winds through the airglow/aurora emissions at wavelengths of 630.0 nm and 557.7 nm, respectively. One FPI (FP01),possessing a large aperture étalon (diameter: 116 mm), was installed at the EISCAT Tromso site in 2009. The other FPIs, using 70-mm diameter étalons, were installed in Thailand, Indonesia, and Australia in 2010-2011 (FP02-FP04) by the Solar-Terrestrial Environment Laboratory, and in Peru (Nazca and Jicamarca) and Alaska (Poker Flat) by Clemson University. The FPIs with 70-mm étalons are low-cost compact instruments, suitable for multipoint network observations. All of these FPIs use low-noise cooled-CCD detectors with 1024 x 1024 pixels combined with a 4-stage thermoelectric cooling system that can cool the CCD temperature down to -80°C. The large incident angle (maximum: 1.3-1.4°.) to the étalon achieved by the use of multiple orders increases the throughput of the FPIs. The airglow and aurora observations at Tromso by FP01 show wind velocities with typical random errors ranging from 2 to 13 m s-1 and from 4 to 27 m s-' for mésosphère (557.7 nm) and thermosphère (630.0 nm) measurements, respectively. The 630.0-nm airglow observations at Shigaraki, Japan, by FP02-FP04 and by the American FPI instruments give thermospheric wind velocities with typical random errors that vary from 2ms to more than 50 m s-l depending on airglow intensity.
机译:我们已经开发出了新的法布里-珀罗干涉仪(FPI),旨在测量分别通过630.0 nm和557.7 nm波长的气辉/极光发射的热层风和温度以及中层风。 2009年在EISCAT Tromso站点安装了一个具有大口径标准具(直径:116毫米)的FPI(FP01)。2010年,在泰国,印度尼西亚和澳大利亚安装了使用直径70毫米标准具的其他FPI。 -2011(FP02-FP04)由太阳地面环境实验室提供,在秘鲁(Nazca和Jicamarca)和阿拉斯加(扑克平台)由Clemson大学提供。具有70毫米标准具的FPI是低成本的紧凑型仪器,适用于多点网络观测。所有这些FPI均使用1024 x 1024像素的低噪声冷却CCD检测器,并结合了可将CCD温度降至-80°C的4级热电冷却系统。通过使用多个订单实现的与标准具的大入射角(最大:1.3-1.4°)增加了FPI的吞吐量。 FP01在特罗姆瑟的气辉和极光观测显示,风速(557.7 nm)和热风(630.0 nm)的典型随机误差分别为2至13 m s-1和4至27 m s-。 FP02-FP04和美国FPI仪器在日本Shigaraki观测到的630.0 nm气辉给出了热球风速,典型的随机误差根据气辉强度而变化,从2ms到大于50 m s-l。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号