Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results.

机译:多层螺旋计算机体层摄影术中髋关节假体的重新格式化投影减少的金属伪影:技术和初步临床结果。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: Hip prosthesis is one of the most common types of metal implants and can cause significant artifacts in computed tomography (CT) examinations. The purpose of this work was to develop a projection-based method for reducing metal artifacts caused by hip prostheses in multislice helical CT. METHOD AND MATERIALS: The proposed method is based on a novel concept, reformatted projection, which is formed by combining the projection data at the same view angle over the full longitudinal scan range. Detection and segmentation of the metal were performed on each reformatted projection image. Two dimensional interpolation based on Delaunay triangulation was used to fill voids left after removal of the metal in the reformatted projection. The corrected data were then reconstructed using a commercially available algorithm. The main advantage of this method is that both the detection of the metal objects and the interpolations are performed on complete reformatted projections with the entire metal region present, which is particularly useful for long hip prostheses. Twenty clinical abdominal/pelvis exams with hip prostheses were corrected and clinically evaluated. RESULTS: The overall image quality and the conspicuity in some critical organs were significantly improved compared with the uncorrected images: overall quality (P = 0.0024); bladder base (P = 0.0027), and rectum (P = 0.0078). The average noise level in the bladder base was reduced from 86.7 HU to 36.2 HU. In 17 of 20 cases, the radiologists preferred either coronal (13) or axial (4) views of the corrected images. CONCLUSIONS: A novel method for reducing metal artifact in multislice helical CT was developed. Initial clinical results showed that the proposed method can effectively reduce the artifacts caused by metal implants for the cases of unilateral and bilateral hip prothesis.
机译:目的:髋关节假体是最常见的金属植入物之一,在计算机断层扫描(CT)检查中会引起明显的伪影。这项工作的目的是开发一种基于投影的方法,以减少多层螺旋CT中由髋关节假体引起的金属假象。方法和材料:所提出的方法基于一种新颖的概念,即重新格式化的投影,该投影是通过在整个纵向扫描范围内以相同视角组合投影数据而形成的。对每个重新格式化的投影图像执行金属的检测和分割。基于Delaunay三角剖分的二维插值用于填充在重新格式化的投影中除去金属后剩下的空隙。然后使用市售算法重建校正后的数据。该方法的主要优点是,在存在整个金属区域的情况下,对完全重新格式化的投影执行金属对象的检测和插值,这对于长髋关节假体特别有用。矫正了20例带有髋关节假体的腹部/骨盆临床检查并进行了临床评估。结果:与未校正图像相比,某些关键器官的整体图像质量和显眼性得到了显着改善:整体质量(P = 0.0024);膀胱底(P = 0.0027)和直肠(P = 0.0078)。膀胱底部的平均噪音水平从86.7 HU降低到36.2 HU。在20例病例中的17例中,放射科医生更喜欢冠状(13)或轴向(4)校正图像。结论:提出了一种减少多层螺旋CT金属伪影的新方法。初步的临床结果表明,对于单侧和双侧髋关节假体,该方法可有效减少金属植入物引起的假象。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号