...
首页> 外文期刊>Investigative ophthalmology & visual science >The Relationship between Visual Field and Retinal Nerve Fiber Layer Measurements in Patients with Multiple Sclerosis.
【24h】

The Relationship between Visual Field and Retinal Nerve Fiber Layer Measurements in Patients with Multiple Sclerosis.

机译:多发性硬化症患者视野与视网膜神经纤维层测量之间的关系。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To investigate the relationship between visual function, measured by standard automated perimetry (SAP), and retinal nerve fiber layer (RNFL) thickness, measured by optical coherence tomography (OCT), in patients with multiple sclerosis (MS). METHODS: SAP and RNFL thickness were measured in patients with MS in 28 eyes with the last optic neuritis (ON) >/=6 months prior (ON group) and 33 eyes without ON history (non-ON group). Abnormal overall or quadrant RNFL thickness was defined by measured values below 5% of the norm. A whole visual field or a sector of the field was classified as abnormal by using cluster criteria on total-deviation plots. Agreement between SAP and OCT results in classifying eyes/sectors was presented as a percentage of observed agreement, along with the AC1 statistic, which corrects for chance agreement. Regression analyses were performed relating several SAP parameters and RNFL thickness in the ON group. RESULTS: ON eyes showed more loss of visual sensitivity (MD, P = 0.02) and more loss of RNFL thickness (P < 0.0001) than did non-ON eyes. SAP and OCT agreed in 86% (AC1 = 0.78) of eyes and 69% (AC1 = 0.38) of sectors in the ON group and 61% (AC1 = 0.33) of eyes and 66% (AC1 = 0.48) of sectors in the non-ON group. Overall RNFL thickness was related to MD (dB) by a simple exponential function (R(2) = 0.48), supporting a linear relationship between these measures when both are expressed on linear scales. Absolute Pearson correlation coefficients for overall RNFL thickness and several SAP parameters ranged from 0.51 to 0.69. CONCLUSIONS: Good agreement between SAP and OCT was found in ON eyes but not in non-ON eyes or in individual sectors in either group. The findings in this study provide further support for the utility of combining structural and functional testing in clinical research on patients with MS, as well as in future neuroprotection trials for which the anterior visual pathways in patients with MS and optic neuritis may be used as a model.
机译:目的:探讨多发性硬化症(MS)患者的视觉功能(通过标准自动视野检查(SAP)测量与视网膜神经纤维层(RNFL)厚度(通过光学相干断层扫描(OCT)测量)之间的关系。方法:对MS患者中28只最后一次视神经炎(ON)> / = 6个月前的眼(ON组)和33例无ON史的患者(非ON组)测量SAP和RNFL厚度。 RNFL总厚度或象限异常是由低于标准值5%的测量值定义的。通过在总偏差图上使用聚类标准,将整个视野或视野的一部分归类为异常。 SAP和OCT之间在对眼睛/行业进行分类的结果中的一致性表示为观察到的一致性的百分比,以及AC1统计量,该统计量用于校正偶然性一致性。对ON组中的几个SAP参数和RNFL厚度进行了回归分析。结果:与非ON眼相比,ON眼显示出更多的视觉敏感性丧失(MD,P = 0.02)和RNFL厚度丧失(P <0.0001)。 SAP和OCT同意ON组中86%(AC1 = 0.78)的眼睛和69%(AC1 = 0.38)的扇形,以及61%(AC1 = 0.33)的眼睛和66%(AC1 = 0.48)的扇形。非ON组。 RNFL的总厚度通过简单的指数函数(R(2)= 0.48)与MD(dB)相关,当这两个度量均以线性标度表示时,支持了这些度量之间的线性关系。整个RNFL厚度和几个SAP参数的绝对Pearson相关系数在0.51至0.69之间。结论:在ON眼中,SAP和OCT之间具有良好的一致性,但在非ON眼或两组中的各个部门中均未发现。这项研究的发现为将结构测试和功能测试结合用于MS患者的临床研究以及未来的神经保护试验提供了进一步的支持,在这些神经保护试验中,MS和视神经炎患者的前路视觉通路可以用作模型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号