Field testing of acoustic cleaning system working in 670MW_(TH) CFB boiler

机译:670MW_(TH)CFB锅炉的声波清洗系统的现场测试

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The article reports the results of measurements of the acoustic pressure of acoustic waves generated by acoustic dust cleaners mounted in the convection pass of the 670MW,h Circulating Fluidised Bed boiler. Based on measurements carried out and the spectral analysis of recorded signals it was found that the level of acoustic pressure generated by acoustic cleaners for the frequency of 100 Hz was too low for the efficient cleaning of the heated surfaces of the reheater RH2 and superheater SH3.
机译:该文章报告了安装在670MW,h循环流化床锅炉对流通道中的吸尘器产生的声波声压的测量结果。根据进行的测量和对记录信号的频谱分析,发现对于100 Hz的频率,吸声清洁器产生的声压水平太低,无法有效清洁再热器RH2和过热器SH3的加热表面。