首页> 外文期刊>International Orthopaedics >Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem.
【24h】

Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem.

机译:30岁以下患者的髋关节置换术:10到16年的随访结果非常出色,使用了HA涂层的茎。

获取原文
获取原文并翻译 | 示例
       

摘要

It is well accepted that youth and high activity levels are among the factors that increase the risk of mechanical failure of total hip prostheses. However, there are few reports of long-term results in very young patients. In this study, we evaluated the results of total 49 hip replacements (THRs) using an uncemented total hip prosthesis in 44 patients (28 females) who were 30 years or younger (range: 15-30 years). The diagnosis was ostearthritis due to congenital dislocations in 28 patients, with the remaining patients having diagnoses of sequelae of fracture, infection, Calve-Legg-Perthes disease, avascular necrosis, chondrodystrophia and epiphyseal dysplasia. In all cases we used an uncemented straight stem fully coated with hydroxyapatite (HA). In 36 cases we used a hemispherical cup inserted with press fit, and in seven cases we used a hemispherical screw cup. The patients were evaluated ten to 16 years (mean: 13 years) after the operation by radiographic and clinical examinations, including the Harris Hip, WOMAC and EuroQol-5D scores. In a sub-group of nine patients with a unilateral prosthesis, the muscle strength of the quadriceps and hamstrings was tested using a Cybex 6000. None of the stems were revised at the follow-up examination, and all were classified as well integrated, with no signs of radiological loosening. Twenty-four hips had revision of the acetabular component due to mechanical failure. The Harris Hip score was, on average, 88 (range: 62-100), the WOMAC score 80 (range: 37-100) and the EuroQol score 0.68 (range: -0.14-1). Isokinetic muscle strength testing showed that seven of the nine tested patients were weaker on the operated side. In conclusion, we found mechanical failures at the acetabular side, but excellent results with a fully HA-coated femoral stem, with no revisions after ten to 16 years.
机译:年轻人和高活动水平是增加全髋关节假体机械衰竭风险的因素之一,这一点已被广泛接受。但是,很少有报道称非常年轻的患者可以获得长期结果。在这项研究中,我们对30岁或更年轻(范围:15-30岁)的44例患者(28名女性)中使用非骨水泥全髋关节置换术评估了总共49例髋关节置换术(THR)的结果。诊断为28例因先天性脱位引起的骨关节炎,其余患者被诊断为骨折,感染,小腿-Legg-Perthes病,无血管坏死,软骨营养不良和骨phy发育不良的后遗症。在所有情况下,我们都使用未涂水泥的直杆,并完全涂上羟基磷灰石(HA)。在36个案例中,我们使用了一个半球形杯,通过压配合插入;在七个案例中,我们使用了一个半球形螺旋杯。术后10到16年(平均13年)对患者进行了影像学检查和临床检查,包括Harris Hip,WOMAC和EuroQol-5D评分。在一个9例单侧假体患者的亚组中,使用Cybex 6000测试了股四头肌和绳肌的肌肉强度。在随访检查中未对任何茎进行修订,所有茎均归类为完全融合,没有放射性松动的迹象。由于机械故障,二十四髋髋臼组件发生翻修。 Harris Hip得分平均为88(范围:62-100),WOMAC得分为80(范围:37-100)和EuroQol得分为0.68(范围:-0.14-1)。等速肌力测试显示,在接受测试的9位患者中,有7位在手术侧较弱。总之,我们发现髋臼侧发生机械故障,但是在完全覆有HA涂层的股骨柄上取得了优异的结果,十到16年后没有任何改变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号