首页> 外文期刊>International Orthopaedics >The outcome of the cementless tapered SL-Plus stem: An analysis of arthroplasty register data
【24h】

The outcome of the cementless tapered SL-Plus stem: An analysis of arthroplasty register data

机译:非骨水泥锥形SL-Plus茎的结果:关节成形术登记数据的分析

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: The aim of this study is to evaluate the outcome of the cementless SL-Plus stem in worldwide arthroplasty register datasets. Methods: A structured analysis was conducted the registered data about the SL-Plus stem manufactured by Smith&Nephew including published data from Australia as well as previously unpublished datasets from the Registers of Lombardia, Italy and Valdoltra, Slovenia. A total of 75% of the data analysed had not been published so far. The primary outcome measure was the revision rate, calculated in revisions per 100 observed component years.We evaluated a total of 10,684 primary and 122 revision surgeries with an average follow-up period of four years. Results: All datasets showed good and reproducible results for treatment with the SL-Plus stem. An average of 0.31 revisions per 100 observed component years had been reported, which is considerably below the worldwide average (1.29) found for total hip arthroplasty independent of the product. The results of a large centre did not essentially deviate from the revision rates in Lombardia, where the numbers of cases per department are relatively low on average. Conclusions: There were no indications for product defects or relevant errors in application. The SL-Plus stem can be considered a high-quality product that ensures good results also in the hands of less experienced surgeons. Data from even young registers can substantially contribute to the assessment of implants, even with the short follow-up periods. These datasets particularly allow for valid assessment of safety issues and can therefore make an essential contribution to the solution of problems of current relevance.
机译:目的:本研究的目的是评估全球置换术注册数据集中无骨水泥SL-Plus茎的结果。方法:对Smith&Nephew生产的SL-Plus茎的注册数据进行了结构化分析,包括来自澳大利亚的公开数据以及来自意大利伦巴第大区和斯洛文尼亚的瓦尔多特拉的先前未公开的数据集。到目前为止,尚未发布分析的数据中的75%。主要结果指标是修订率,以每100个观察年的修订数计算。我们评估了总共10,684例初级手术和122个修订手术,平均随访期为4年。结果:所有数据集均显示使用SL-Plus茎杆治疗可获得良好且可重复的结果。据报道,每100个观察组年平均进行0.31次修订,这大大低于与产品无关的全髋关节置换术的全球平均值(1.29)。一个大型中心的结果基本上没有偏离伦巴第大区的修订率,伦巴第大区每个部门的案件数量平均相对较低。结论:没有迹象表明产品存在缺陷或相关的应用错误。 SL-Plus阀杆可以被认为是高质量的产品,即使经验不足的外科医生也可以确保获得良好的效果。即使是很短的随访期,即使是年轻的登记员的数据也可以大大有助于评估植入物。这些数据集尤其允许对安全问题进行有效评估,因此可以为解决当前相关问题做出重要贡献。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号