首页> 外文期刊>Interventional neuroradiology: journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences >A 6-Fr guiding catheter (Slim Guide?) for use with multiple microdevices: An experimental study
【24h】

A 6-Fr guiding catheter (Slim Guide?) for use with multiple microdevices: An experimental study

机译:用于多种微型设备的6-Fr导向导管(Slim Guide?):一项实验研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A modified technique is required in patients with wide-necked aneurysms whose treatment by the single microcatheter technique is difficult. We developed a 6-Fr guiding catheter (Slim Guide?) that features a large lumen (0.072 inch) for performing the modified technique. To evaluate the usefulness of Slim Guide? we carried out experiments using three types of 6-Fr guiding catheter. In experiment 1, the shaft hardness and kink resistance were compared among three different guiding catheters (Slim Guide?, Launcher?, Envoy?). In experiment 2, we inserted a microballoon catheter and a microcatheter into the three different guiding catheters and recorded the maximal infusion pressure. In experiment 3, we inserted 13 different types of microdevices into the three different guiding catheters and evaluated the resistance of the microdevices. Although the shaft of the Slim Guide? was softer than that of the other two guiding catheters, its kink resistance was comparable. The maximal infusion pressure was significantly lower than with Launcher? or Envoy? catheters. Furthermore, with Slim Guide?, in 136 of 143 microdevice combinations examined (95.1%) there was no resistance; this was true for 125 (87.4%) and 116 (81.1%) combinations using the Launcher? - and the Envoy? guiding catheters, respectively. There was a significant difference between Slim Guide? and the other two guiding catheters with respect to their accommodation of double microsystems (p<0.05). Although the inner diameter of Slim Guide? is slightly larger than of the other two guiding catheters, it significantly increased the combination of microdevices that could be used for the coil embolization of difficult aneurysms.
机译:对于单颈导管技术难以治疗的宽颈动脉瘤患者,需要改良的技术。我们开发了6-Fr导向导管(Slim Guide?),该导管具有较大的管腔(0.072英寸),可以进行改良的技术。要评估Slim Guide的有用性?我们使用三种类型的6-Fr引导导管进行了实验。在实验1中,比较了三种不同导管(Slim Guide?,Launcher?,Envoy?)的杆身硬度和抗扭结性。在实验2中,我们将微气球导管和微导管插入三个不同的导管中,并记录了最大输液压力。在实验3中,我们将13种不同类型的微型设备插入三个不同的引导导管中,并评估了微型设备的电阻。虽然是Slim Guide的轴?比其他两个引导导管柔软,其抗扭结性可比。最大输液压力明显低于Launcher?还是特使?导管。此外,使用Slim Guide ?,在检查的143个微型设备组合中的136个(95.1%)中,没有阻力。使用启动器的125(87.4%)和116(81.1%)组合是否正确? -和特使?分别引导导管。 Slim Guide之间有显着差异吗?以及其他两个引导导管对双微系统的适应性(p <0.05)。虽然Slim Guide的内径?它比其他两个引导导管稍大一些,因此显着增加了可用于困难动脉瘤的线圈栓塞的微型设备的组合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号