The paper presents an advanced numerical study of industrial switchgear with the joint electric resistance included. The fundamental thermal problems (radiation, convection and conduction) in copper busbars, supporting parts and cooling air were coupled with the electromagnetic field to accurately define the power losses. The mathematical model was based on the validated model of the simplified laboratory switchgear. However, more sophisticated busbar system was employed in this study. The model results were compared with the measurements data for two switchgear configurations of different type of a top cover, i.e. ventilated and solid ones. Then, the "what-if' studies for basic configuration were considered. In the considered problem, the influence of the busbar surface emissivity modification, the changes in enclosure inlet/outlet grids and application of the radiator without fan on the local and global temperature reduction within the switchgear was analysed. The results obtained show the importance of radiative heat transfer and emphasize the influence of the surface emissivity in the switchgear cooling process. (C) 2016 Elsevier Masson SAS. All rights reserved.
机译:本文介绍了包括联合电阻在内的工业开关设备的高级数值研究。铜母线,支撑部件和冷却空气中的基本热问题(辐射,对流和传导)与电磁场结合在一起,可以准确地确定功率损耗。数学模型基于简化的实验室开关柜的验证模型。然而,在这项研究中采用了更复杂的母线系统。将模型结果与两种不同顶盖类型(即通风和实心)的开关柜配置的测量数据进行比较。然后,考虑了基本配置的“假设”研究,在所考虑的问题中,母线表面发射率修改,外壳进/出口栅格的变化以及无风扇散热器的应用对局部和全局温度的影响分析了开关设备中的气体减少量,获得的结果表明了辐射传热的重要性,并强调了表面发射率在开关设备冷却过程中的影响(C)2016 Elsevier Masson SAS。保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号