摘要

Load angle δ, by definition is the angular displacement between the excitation voltage E and the terminal voltage V of the generator. Its value is a useful parameter of the synchronous generator in relation to its stability limit. The estimation of this parameter is of utmost importance since its value can be used as a measure of how close the generator is to pole-slipping and thus can be operated near its stability limit. This paper focuses on the simulation of synchronous generator load angle estimation using SIMULINK. It deployed the voltage-current vector diagram and linearized form of swing equation in building the simulink blocks. Results obtained revealed that load angle value remains constant during steady-state operation but a swing results when a disturbance is introduced into the system.
机译:根据定义,负载角δ是励磁电压E和发电机端电压V之间的角位移。就其稳定性极限而言,其值是同步发电机的有用参数。该参数的估计是最重要的,因为其值可以用作衡量发电机接近极滑的程度的指标,因此可以在其稳定极限附近运行。本文着重于使用SIMULINK进行同步发电机负载角估计的仿真。在构建simulink模块时,它采用了电压-电流矢量图和摆动方程的线性化形式。获得的结果表明,负载角值在稳态操作期间保持恒定,但在将干扰引入系统时会产生摆动。