OBJECTIVES: To improve the integration of MRI with radiotherapy treatment planning, our department fabricated a flat couch top for our MR scanner. Setting up using this couch top meant that the patients were physically higher up in the scanner and, posteriorly, a gap was introduced between the patient and radiofrequency coil. METHODS: Phantom measurements were performed to assess the quantitative impact on image quality. A phantom was set up with and without the flat couch insert in place, and measurements of image uniformity and signal to noise were made. To assess clinical impact, six patients with pelvic cancer were recruited and scanned on both couch types. The image quality of pairs of scans was assessed by two consultant radiologists. RESULTS: The use of the flat couch insert led to a drop in image signal to noise of approximately 14%. Uniformity in the anteroposterior direction was affected the most, with little change in right-to-left and feet-to-head directions. All six patients were successfully scanned on the flat couch, although one patient had to be positioned with their arms by their sides. The image quality scores showed no statistically significant change between scans with and without the flat couch in place. CONCLUSION: Although the quantitative performance of the coil is affected by the integration of a flat couch top, there is no discernible deterioration of diagnostic image quality, as assessed by two consultant radiologists. Although the flat couch insert moved patients higher in the bore of the scanner, all patients in the study were successfully scanned.
机译:目的:为了改善MRI与放射治疗计划的集成,我们的部门为MR扫描仪制造了一个扁平的沙发顶。使用此沙发床架进行安装意味着患者在扫描仪中的身体更高,并且随后在患者和射频线圈之间引入了间隙。方法:进行了幻像测量以评估对图像质量的定量影响。在有和没有平坦沙发插入物的情况下,都建立了幻像,并进行了图像均匀性和信噪比的测量。为了评估临床影响,招募了6名骨盆癌患者,并在这两种沙发上进行了扫描。两名顾问放射科医生评估了扫描对的图像质量。结果:使用平卧榻插件会导致图像信号噪声下降约14%。前后方向的均匀性受影响最大,从右到左和从脚到头的方向变化很小。所有六名患者均已在平坦的沙发上成功扫描,尽管其中一名患者必须将手臂放在两侧。图像质量得分显示,在有或没有平坦沙发的情况下,扫描之间的统计变化均无统计学意义。结论:尽管线圈的定量性能受平板沙发顶的集成度的影响,但如两位顾问放射科医生所评估的那样,诊断图像质量没有明显的下降。尽管平坦的卧榻插入物使患者在扫描仪孔中的位置更高,但研究中的所有患者均已成功扫描。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号