首页> 外文期刊>International journal of sports medicine >Absolute reliability of hamstring to quadriceps strength imbalance ratios calculated using peak torque, joint angle-specific torque and joint ROM-specific torque values
【24h】

Absolute reliability of hamstring to quadriceps strength imbalance ratios calculated using peak torque, joint angle-specific torque and joint ROM-specific torque values

机译:peak绳肌与股四头肌力量不平衡率的绝对可靠性,使用峰值扭矩,关节角度特定扭矩和关节ROM特定扭矩值计算得出

获取原文
获取原文并翻译 | 示例
           

摘要

The main purpose of this study was to determine the absolute reliability of conventional (H/Q CONV) and functional (H/Q FUNC) hamstring to quadriceps strength imbalance ratios calculated using peak torque values, 3 different joint angle-specific torque values (10°, 20° and 30° of knee flexion) and 4 different joint ROM-specific average torque values (010°, 1120°, 2130° and 030° of knee flexion) adopting a prone position in recreational athletes. A total of 50 recreational athletes completed the study. H/Q CONV and H/Q FUNC ratios were recorded at 3 different angular velocities (60, 180 and 240°/s) on 3 different occasions with a 72-96h rest interval between consecutive testing sessions. Absolute reliability was examined through typical percentage error (CV TE), percentage change in the mean (CM) and intraclass correlations (ICC) as well as their respective confidence limits. H/Q CONV and H/Q FUNC ratios calculated using peak torque values showed moderate reliability values, with CM scores lower than 2.5%, CV TE values ranging from 16 to 20% and ICC values ranging from 0.3 to 0.7. However, poor absolute reliability scores were shown for H/Q CONV and H/Q FUNC ratios calculated using joint angle-specific torque values and joint ROM-specific average torque values, especially for H/Q FUNC ratios (CM: 1-23%; CV TE: 22-94%; ICC: 0.1-0.7). Therefore, the present study suggests that the CV TE values reported for H/Q CONV and H/Q FUNC (≈18%) calculated using peak torque values may be sensitive enough to detect large changes usually observed after rehabilitation programmes but not acceptable to examine the effect of preventitive training programmes in healthy individuals. The clinical reliability of hamstring to quadriceps strength ratios calculated using joint angle-specific torque values and joint ROM-specific average torque values are questioned and should be re-evaluated in future research studies.
机译:这项研究的主要目的是确定常规(H / Q CONV)和功能性(H / Q FUNC)ham绳肌与股四头肌力量不平衡比率的绝对可靠性,该比率使用峰值扭矩值,3种不同的关节角度特定扭矩值(10膝关节屈曲度分别为0°,20°和30°)和4个不同的关节ROM特定的平均扭矩值(膝部屈曲为010°,1120°,2130°和030°),这些姿势在休闲运动员中很容易出现。共有50名休闲运动员完成了这项研究。在3种不同情况下,在3种不同的角速度(60、180和240°/ s)下记录了H / Q CONV和H / Q FUNC比,连续两次测试之间的休息间隔为72-96h。通过典型百分比误差(CV TE),均值变化百分比(CM)和组内相关性(ICC)以及它们各自的置信度极限来检查绝对可靠性。使用峰值扭矩值计算的H / Q CONV和H / Q FUNC比显示出中等的可靠性值,CM分数低于2.5%,CV TE值介于16%至20%之间,ICC值介于0.3至0.7之间。但是,使用关节角度特定的扭矩值和关节ROM特定的平均扭矩值计算的H / Q CONV和H / Q FUNC比的绝对可靠性得分差,尤其是对于H / Q FUNC比(CM:1-23% ; CV TE:22-94%; ICC:0.1-0.7)。因此,本研究表明,使用峰值扭矩值计算出的H / Q CONV和H / Q FUNC(≈18%)报告的CV TE值可能足够灵敏以检测通常在康复计划后观察到的大变化,但无法接受检查预防性培训计划对健康个体的影响。使用关节角度特定扭矩值和关节ROM特定平均扭矩值计算的绳肌与股四头肌力量比的临床可靠性受到质疑,应在以后的研究中重新评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号