PURPOSE: Microdosimetric measurements were performed at Massachusetts General Hospital, Boston, MA, to assess the dose equivalent external to passively delivered proton fields for various clinical treatment scenarios. METHODS AND MATERIALS: Treatment fields evaluated included a prostate cancer field, cranial and spinal medulloblastoma fields, ocular melanoma field, and a field for an intracranial stereotactic treatment. Measurements were completed with patient-specific configurations of clinically relevant treatment settings using a silicon-on-insulator microdosimeter placed on the surface of and at various depths within a homogeneous Lucite phantom. The dose equivalent and average quality factor were assessed as a function of both lateral displacement from the treatment field edge and distance downstream of the beam's distal edge. RESULTS: Dose-equivalent value range was 8.3-0.3 mSv/Gy (2.5-60-cm lateral displacement) for a typical prostate cancer field, 10.8-0.58 mSv/Gy (2.5-40-cm lateral displacement) for the cranial medulloblastoma field, 2.5-0.58 mSv/Gy (5-20-cm lateral displacement) for the spinal medulloblastoma field, and 0.5-0.08 mSv/Gy (2.5-10-cm lateral displacement) for the ocular melanoma field. Measurements of external field dose equivalent for the stereotactic field case showed differences as high as 50% depending on the modality of beam collimation. Average quality factors derived from this work ranged from 2-7, with the value dependent on the position within the phantom in relation to the primary beam. CONCLUSIONS: This work provides a valuable and clinically relevant comparison of the external field dose equivalents for various passively scattered proton treatment fields.
机译:目的:在马萨诸塞州波士顿的马萨诸塞州综合医院进行了微剂量测量,以评估各种临床治疗方案中被动输送质子场外部的等效剂量。方法和材料:评估的治疗领域包括前列腺癌领域,颅和脊髓髓母细胞瘤领域,眼黑素瘤领域以及颅内立体定向治疗领域。使用放置在均质Lucite体模表面上和不同深度内的绝缘体上硅微量剂量计,使用针对患者的临床相关治疗设置来完成测量。等效剂量和平均质量因数被评估为距治疗区域边缘的侧向位移和束远端边缘下游距离的函数。结果:典型前列腺癌场的剂量当量值范围为8.3-0.3 mSv / Gy(2.5-60 cm侧向位移),颅脑髓母细胞瘤场的剂量当量值范围为10.8-0.58 mSv / Gy(2.5-40 cm侧向位移) ,对于脊髓髓母细胞瘤场为2.5-0.58 mSv / Gy(横向位移5-20 cm),对于眼黑素瘤场为0.5-0.08 mSv / Gy(横向位移2.5-10-cm)。立体定向场情况下的等效外场剂量测量结果显示,取决于光束准直的方式,差异高达50%。从这项工作得出的平均质量因子在2-7之间,其值取决于体模中相对于主光束的位置。结论:这项工作为各种被动分散的质子治疗领域的外场剂量当量提供了有价值的和临床相关的比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号