首页> 外文期刊>International journal of rehabilitation research: Internationale Zeitschrift fur Rehabilitationsforschungon >Psychometric properties of fatigue severity and fatigue impact scales in postpolio patients
【24h】

Psychometric properties of fatigue severity and fatigue impact scales in postpolio patients

机译:polipoli后患者的疲劳严重程度和疲劳影响量表的心理计量学特性

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

We evaluate the reliability, validity, and responsiveness of the Fatigue Severity Scale (FSS) and the Fatigue Impact Scale (FIS) and to determine whether these scales are potentially applicable for measuring fatigue in postpolio patients (PPS). After the Turkish adaptation of FSS and FIS using a forward-backward procedure, the scales were administered to 48 PPS patients without additional health problems that may induce fatigue. Reliability studies were carried out by determination of intraclass correlation coefficient and internal consistency by the Cronbach-α coefficient. Validity was tested by within-scale analyses and analyses against the external criteria including convergent validity and discriminant validity. Correlations with the Notthingham Health Profile (NHP), fatigue, pain and cramp severity (visual analog scale), and manual muscle testing were performed. Sensitivity to changes was determined by standardized response mean values. All patients completed scales, suggesting their satisfactory acceptance. Reliability studies were satisfactory, with higher Cronbach-α values and intraclass correlation coefficients than 0.80. The FSS score was correlated moderately with visual analog scale-fatigue (r=0.41) and the NHP-energy dimension (r=0.29). All FIS scores except cognitive scores were moderately related to the NHP-social isolation score (r=0.40, 0.37, and 0.43 for FIS-physical, social, and total scores, respectively). There was also a significant correlation between the FIS-physical score and the NHP-energy score (r=0.31). On the basis of the standardized response mean values, response to treatment for these two questionnaires was satisfactory (P=0.00). The Turkish versions of FSS and FIS were reliable, sensitive to clinical changes, and also well accepted by patients with PPS. Although they had somewhat satisfactory convergent validity, the absence of strong correlations did not support the validity entirely.
机译:我们评估疲劳严重程度量表(FSS)和疲劳影响量表(FIS)的可靠性,有效性和响应度,并确定这些量表是否可能适用于测量后政治患者的疲劳程度(PPS)。在土耳其使用向前-向后程序对FSS和FIS进行调整之后,将秤用于48名PPS患者,而没有其他可能引起疲劳的健康问题。通过使用Cronbach-α系数确定组内相关系数和内部一致性来进行可靠性研究。通过规模内分析和针对外部标准(包括收敛效度和判别效度)的分析来检验效度。与诺丁汉健康档案(NHP),疲劳,疼痛和抽筋严重程度(视觉模拟评分)以及手动肌肉测试进行了相关。对变化的敏感性由标准化的响应平均值确定。所有患者均已完成量表,表明他们满意。可靠性研究令人满意,Cronbach-α值更高,并且组内相关系数超过0.80。 FSS评分与视觉模拟量表疲劳(r = 0.41)和NHP能量维度(r = 0.29)有适度的相关性。除认知评分外,所有FIS评分均与NHP-社会隔离评分有中等相关性(FIS身体,社会和总评分分别为r = 0.40、0.37和0.43)。 FIS物理评分与NHP能量评分之间也存在显着相关性(r = 0.31)。根据标准化的答复平均值,这两个问卷对治疗的答复令人满意(P = 0.00)。 FSS和FIS的土耳其语版本可靠,对临床变化敏感,也为PPS患者所接受。尽管它们具有令人满意的收敛效度,但缺乏强相关性并不能完全支持效度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号