首页> 外文期刊>Topics in stroke rehabilitation >Psychometric properties of an Arabic version of the fatigue severity scale in patients with stroke
【24h】

Psychometric properties of an Arabic version of the fatigue severity scale in patients with stroke

机译:中风患者疲劳严重规模阿拉伯语版本的心理测量特性

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Post-stroke fatigue is a common symptom which needs to be assessed by a psychometrically sound tool. Objectives: To investigate the psychometric properties of an Arabic version of the fatigue severity scale (FSS-A) in patients with stroke. Methods: An observational, cross-sectional design was applied to 147 survivors of first-time stroke and 70 healthy participants. Internal consistency was measured by Cronbach's alpha, while test-retest reliability was measured by intraclass correlation coefficients (ICCs). To assess validity, the FSS-A was correlated with the Fatigue Visual Analogue Scale (VAS-F), the Short Form 36 (SF-36) and its vitality domain (SF-36V), the stroke specific quality of life (SSQOL-A) and its energy domain (SSQOL-A-E), and the Beck Depression Inventory II (BDI-II). Results: The FSS-A showed excellent internal consistency (Cronbach's alpha = 0.934) and test-retest reliability (ICC = 0.920, 95% confidence interval (CI): 0.85-0.96). Exploratory factor analysis confirmed that the FSS-A is unidimensional. The FSS-A had high positive correlation with VAS-F, moderate positive correlation with BDI-II, high negative correlation with SSQOL-A-E and moderate negative correlations with SF-36, SF-36V, and SSQOL-A. It differentiated patients from healthy participants with a sensitivity of 78.4% and a specificity of 77.1%. The minimal detectable change with 95% CI was 1.02 (22.4%). Conclusions: The FSS-A showed good psychometric properties suggesting its usefulness as a fatigue evaluation tool in patients diagnosed with stroke.
机译:背景:后卒中后疲劳是一种常见的症状,需要通过精神度计的声音工具进行评估。目的:探讨卒中患者疲劳严重程度(FSS-A)的阿拉伯语版本的心理测量特性。方法:将观察到的横截面设计应用于首次中风和70名健康参与者的147名幸存者。通过Cronbach的alpha测量内部一致性,而通过脑内相关系数(ICC)测量测试保持可靠性。为了评估有效性,FSS-A与疲劳视觉模拟量表(VAS-F),短的36(SF-36)及其活力域(SF-36V)相关,中风具体的生命质量(SSQOL- a)及其能量域(ssqol-ae)和Beck抑郁库存II(BDI-II)。结果:FSS-A显示出优异的内部一致性(Cronbach的alpha = 0.934)和测试 - 保持可靠性(ICC = 0.920,95%置信区间(CI):0.85-0.96)。探索性因子分析证实,FSS-A是单向的。 FSS-A与VAS-F具有高的正相关,与BDI-II的中度正相关,与SSQOL-A-E的高负相关,与SF-36,SF-36V和SSQOL-A的中等负相关。它与健康参与者的患者分化为78.4%的敏感性,特异性为77.1%。 95%CI的最小可检测变化为1.02(22.4%)。结论:FSS-A表现出良好的心理测量性质,表明其作为患者诊断卒中患者疲劳评估工具的用途。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号