Two different in vitro tests for pyrogens, using human peripheral blood monocytes (PBMNC) and diluted whole blood (WBC), respectively, were applied to different classes of parenteral medicinal products. Many of these products did not have a specified endotoxin limit concentration that was established as the maximum valid dilution to comply with the test. The results of the in vitro tests for pyrogens were compared with the results from the Limulus amoebocyte lysate (LAL) and rabbit pyrogen tests. The Second International Standard for endotoxin was used to calibrate all of the assays and the International Standard for IL-6 was used to calibrate the IL-6 ELISA which provided the readout for the in vitro tests for pyrogens. Preparatory tests were conducted to ensure that the "criteria for validity and precision of the standard curve" were satisfied and that the drugs being tested did not interfere in the tests. The PBMNC/IL-6 test had a detection limit of 0.06EU/ml and spike recoveries were 62-165%. The whole blood/IL-6 test also had a detection limit of 0.06EU/ml and spike recoveries were 58-132%. The application to the detection of non-endotoxin pyrogens needs to be evaluated in more detail, but the two in vitro tests for pyrogens showed good agreement overall, both with each other and with the LAL test and the rabbit pyrogen test for the detection of endotoxins.
机译:分别使用人外周血单核细胞(PBMNC)和稀释的全血(WBC)进行的两种不同的热原体外试验分别应用于不同类别的肠胃外药品。这些产品中有许多没有规定的内毒素极限浓度,该极限浓度被确定为符合测试的最大有效稀释度。将体外热原测试结果与Li变形细胞裂解液(LAL)和兔热原测试结果进行了比较。内毒素第二国际标准用于校准所有测定,IL-6国际标准用于校准IL-6 ELISA,这为体外热原检测提供了依据。进行了准备测试,以确保满足“标准曲线的有效性和精确度标准”,并且被测药物不会干扰测试。 PBMNC / IL-6测试的检出限为0.06EU / ml,加标回收率为62-165%。全血/ IL-6测试的检出限也为0.06EU / ml,加标回收率为58-132%。需要更详细地评估在检测非内毒素热原方面的应用,但是两次体外热原测试在总体上以及彼此之间以及与用于检测内毒素的LAL测试和兔热原测试之间都显示出良好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号