Effect of multislice scanners on patient dose from routine CT examinations in East Anglia.

机译:多层扫描仪对东安格利亚常规CT检查患者剂量的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

As part of the dose optimization process, the Ionising Radiation (Medical Exposure) Regulations 2000 include requirements relating to the assessment of patient dose, and the setting and subsequent review of diagnostic reference levels. In East Anglia, audits of effective dose in CT have been carried out in 1996, 1999 and 2002. In the 2002 audit, nine of the 14 scanners assessed had been replaced since the previous audit. Eight of the new scanners were multislice scanners, acquiring up to 16 slices in a single rotation. The objective of the 2002 audit was to investigate the effect of the introduction of these multislice scanners on patient doses from routine CT examinations. Exposure parameters were collected for 10 different types of routine CT examination. In excess of 550 sets of patient data were obtained. For each of these, effective doses were calculated using the results of Monte Carlo simulations published by the National Radiological Protection Board. Averaged across all 10 examinations, regional mean effective doses are 34% higher than in 1999. The multislice scanners in the region give, on average, 35% more effective dose than the single-slice scanners. The effect of collimation in multislice scanners makes these effective dose differences most notable for examinations that use narrow slice widths. Further optimization of exposures on multislice scanners has the potential to reduce the differences observed between single-slice and multislice doses. However, when taken in combination with the increased use of CT in many hospitals, the effective dose increases observed are likely to result in a significant increase in the already substantial collective radiation dose from CT.
机译:作为剂量优化过程的一部分,《 2000年电离辐射(医疗照射)条例》包括有关评估患者剂量,设定和随后检查诊断参考水平的要求。在东安格利亚,已于1996年,1999年和2002年对CT的有效剂量进行了审核。在2002年的审核中,自上次审核以来,被评估的14台扫描仪中有9台被更换。新的扫描仪中有八台是多层扫描仪,一次旋转可获取多达16个切片。 2002年审核的目的是调查这些多层扫描仪的引入对常规CT检查对患者剂量的影响。收集了10种不同类型的常规CT检查的暴露参数。获得了超过550套患者数据。对于每种方法,均使用美国国家放射防护局发布的蒙特卡洛模拟结果计算有效剂量。在所有10项检查中平均得出的结果,区域平均有效剂量比1999年高出34%。该区域的多层扫描仪平均有效剂量比单层扫描仪平均高35%。多层扫描仪中的准直效果使这些有效剂量差异对于使用较窄切片宽度的检查最为明显。在多层扫描仪上进一步优化曝光量有可能减小单层和多层剂量之间观察到的差异。但是,当在许多医院中结合使用CT的增加而使用时,观察到的有效剂量增加很可能导致已经相当大的CT集体辐射剂量显着增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号