摘要

We investigated the influence of Holter duration on the detection of recurrences after ablation for atrial fibrillation (AF). Two-hundred-and-fifteen patients underwent a 7-day Holter ECG at 6 months after catheter ablation. We analyzed the number of patients who had a recurrence within the first 24, 48, 72 h etc. up to the total of 7 days. During the complete 7-day recording, 30% had a recurrence. All Holter durations < 5 days would have detected significantly less patients with recurrence than the complete 7-day recording. A 24-hour Holter would have detected 59%, a 48-hour Holter 67% and a 72-hour Holter 80% of patients with recurrences, whereas a 4-day recording would have detected 91% of the recurrences that were detected with the complete 7-day recording. In conclusion, a Holter duration of less than 4 days misses a great portion of recurrences, whereas a 4-day recording might offer a reasonable compromise.
机译:我们调查了动态心电图持续时间对房颤消融后复发检测的影响。导管消融后6个月,有255例患者接受了7天的动态心电图检查。我们分析了在最初的24、48、72 h等至7天之内复发的患者数量。在完整的7天录制期间,有30%的患者复发了。所有Holter持续时间少于5天的患者,与完整7天的记录相比,发现的复发患者明显减少。 24小时动态心电图可检测出59%的复发患者,48小时动态心电图可检测到67%的患者,而72小时动态心电图则可检测到80%的患者复发,而4天记录将检测出91%的复发患者。完成7天的录音。总之,动态心电图的持续时间少于4天会错过很大一部分复发,而4天的录音可能会提供合理的折衷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号