首页> 外文期刊>British journal of ophthalmology >A novel Ocular Anaesthetic Scoring System, OASS, tool to measure both motor and sensory function following local anaesthesia.
【24h】

A novel Ocular Anaesthetic Scoring System, OASS, tool to measure both motor and sensory function following local anaesthesia.

机译:一种新颖的眼科麻醉计分系统OASS,可在局部麻醉后测量运动和感觉功能。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND/AIMS: To devise and evaluate a novel Ocular Anaesthetic Scoring System (OASS) for non-topical local anaesthesia. METHODS: In OASS, a score of between 0 (poor) and 14 (excellent) was devised measuring motor (ocular motility, levator and orbicularis function) and sensory functions (digital spear pressure at limbus and topical anaesthetic sting). 40 patients were studied prospectively to analyse interobserver consistency in OASS. A further 100 patients were collected into four groups receiving either sub-Tenon or peribulbar block with 150 or 300 units of hyaluronidase. Patient satisfaction was determined using the Visual Analogue Pain Scale and Iowa Satisfaction with Anaesthesia Scale. RESULTS: There was no significant difference in OASS scores between two independent observers (p = 0.8910). The sub-Tenon approach achieved significantly better OASS scores than the peribulbar approach (p<0.0004). 300 units of hyaluronidase gave significantly higher OASS scores in both sub-Tenon (p<0.0001) and peribulbar groups (p<0.0001). Spearman rank correlation showed that OASS correlates significantly with VAPS (-0.82, p<0.0001) and ISAS (0.70, p<0.0001). The median satisfaction score was significant in order of magnitude: sub-Tenon with 300 units of hyaluronidase>sub-Tenon with 150 units of hyaluronidase>peribulbar with 300 units of hyaluronidase>peribulbar with 150 units of hyaluronidase. CONCLUSION: OASS is a simple and robust system for assessing and comparing non-topical local anaesthetic techniques. Of the techniques evaluated, a sub-Tenon block with 300 units of hyaluronidase gives the best anaesthesia, analgesia and patient satisfaction results.
机译:背景/目的:设计和评估一种新型的非局部局麻药眼科麻醉计分系统(OASS)。方法:在OASS中,设计了0分(差)至14分(优秀)之间的分数,用于测量运动(眼球运动,提肌和眼轮功能)和感觉功能(角膜缘的数字矛压和局部麻醉性刺痛)。前瞻性研究40例患者,以分析OASS中观察者间的一致性。进一步将100例患者分为四组,分别接受150或300单位透明质酸酶治疗的Tenon或球周周围阻滞。使用视觉模拟疼痛量表和爱荷华州麻醉满意度表确定患者满意度。结果:两个独立的观察者之间的OASS评分没有显着差异(p = 0.8910)。筋膜下入路的OASS评分明显好于球旁入路(p <0.0004)。 300个单位的透明质酸酶在亚特农组(p <0.0001)和球周组(p <0.0001)中的OASS得分均显着较高。 Spearman等级相关性显示OASS与VAPS(-0.82,p <0.0001)和ISAS(0.70,p <0.0001)显着相关。中位满意度得分在数量级上是显着的:具有300单位透明质酸酶的亚特农>具有150单位透明质酸酶的亚特农>具有300单位透明质酸酶的周球>具有150单位透明质酸酶的周球。结论:OASS是一种用于评估和比较非局部局部麻醉技术的简单而强大的系统。在所评估的技术中,具有300个单位的透明质酸酶的Tenon亚阻滞可提供最佳的麻醉,镇痛和患者满意度结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号