Background/aims Diagnosis of rejection in the mouse model of corneal transplantation is based on subjective judgement of loss of graft transparency. The aims of this study were to (1) evaluate a pachymetry technique to measure changes in mouse corneal thickness and (2) correlate increases in transplant thickness with clinical and histological features of rejection. Methods Orthotopic corneal allografts (C57BL/6 strain donor) and syngeneic grafts were performed in A/J mice. Graft transparency was graded and corneal thickness measured by pachymetry on alternate days. Transverse sections of donor cornea excised from eyes representative of clinical opacity grades 1-4 were prepared, photographed, graft section thickness measured and stromal graft-infiltrating cells counted. Intraobserver and interobserver variations in pachymetry were statistically tested.Results Graft thickness, as measured by pachymetry, increased with each clinical opacity grade. Thickness for opacity grades 0, 1 and 2 was less than 300 u.m in all recipients. Graft thickness for grades 3 and 4 was greater than 300 urn in all cases. For measurements up to 400 urn, there was a good correlation between thickness as measured by in vivo pachymetry and in histopathological sections. The mean interobserver bias was -11.35 urn, while the mean intraobserver bias was +3.96 urn. Stromal cellularity increased with increasing corneal thickness up to approximately 300 urn. Conclusion In vivo graft pachymetry provides a new and reliable way to objectively diagnose rejection in the mouse model of corneal transplantation.
机译:背景/目的角膜移植小鼠模型排斥反应的诊断是基于主观判断移植物透明性丧失。这项研究的目的是(1)评估一种测厚技术,以测量小鼠角膜厚度的变化,(2)将移植厚度的增加与排斥反应的临床和组织学特征相关联。方法在A / J小鼠中进行原位角膜移植(C57BL / 6品系供体)和同种异体移植。隔天对移植物的透明度进行分级,并通过测厚法测量角膜厚度。从代表临床不透明等级1-4的眼睛切下的供体角膜的横切面被制备,照相,测量移植物切片厚度并计数基质移植物浸润细胞。统计学上测试了观察者内部和观察者之间的差异。结果通过厚度测定法测定的移植物厚度随每个临床不透明度等级而增加。在所有接受者中,不透明度等级0、1和2的厚度均小于300u.m。在所有情况下,3级和4级的接枝厚度均​​大于300。对于最大400 n的测量,通过体内测厚法测量的厚度与组织病理学切片之间存在良好的相关性。观察者平均偏倚为-11.35 n,观察者平均偏倚为+3.96 n。基质细胞随着角膜厚度的增加而增加,直至约300 um。结论体内移植测厚法为客观诊断角膜移植小鼠排斥反应提供了一种新的可靠方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号