Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography.

机译:旋转Scheimpflug相机,超声测厚仪和扫描狭缝角膜地形图测量中央角膜厚度的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. DESIGN: Experimental study. PARTICIPANTS: Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. METHODS: Corneal thickness measurements were compared among the 3 methods in 54 eyes of 54 subjects. Two sets of measurements were repeated by a single examiner for each pachymetry in another 10 eyes of 5 subjects, and the intraexaminer repeatability was assessed as the absolute difference of the first and second measurements. Two experienced examiners took one measurement for each pachymetry in another 10 eyes of 5 subjects, and the interexaminer reproducibility was assessed as the absolute difference of the 2 measurements of the first and second examiners. MAIN OUTCOME MEASURES: Central corneal thickness measurements by the 3 methods, absolute difference of the first and second measurements by a single examiner, absolute difference of the 2 measurements by 2 examiners, and relative amount of variation. RESULTS: The average measurements of central corneal thickness by a rotating Scheimpflug camera, scanning-slit topography, and ultrasonic pachymetry were 538+/-31.3 microm, 541+/-40.7 microm, and 545+/-31.3 microm, respectively. There were no statistically significant differences in the measurement results among the 3 methods (P = 0.569, repeated-measures analysis of variance). There was a significant linear correlation between the rotating Scheimpflug camera and ultrasonic pachymetry (r = 0.908, P<0.0001), rotating Scheimpflug camera and scanning-slit topography (r = 0.930, P<0.0001), and ultrasonic pachymetry and scanning-slit topography (r = 0.887, P<0.0001). Ultrasonic pachymetry had the smallest intraexaminer variability, and scanning-slit topography had the largest intraexaminer variability among the 3 methods. There were similar variations in interexaminer reproducibility amongthe 3 methods. CONCLUSIONS: Mean corneal thicknesses were comparable among rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit topography with the acoustic equivalent correction factor. The measurements of the 3 instruments had significant linear correlations with one another, and all methods had highly satisfactory measurement repeatability.
机译:目的:比较通过旋转的Scheimpflug相机,超声测厚仪和扫描狭缝角膜地形图/测厚仪拍摄时中心角膜厚度测量值及其可重复性。设计:实验研究。参与者:64位受试者中的74只眼没有白内障以外的眼部异常。方法:比较54名受试者的54只眼的3种方法中的角膜厚度测量结果。由一名检查者对5位受试者的另外10眼中的每个测厚法重复进行两组测量,并将检查者内重复性作为第一次和第二次测量的绝对差。两名经验丰富的检查员在5位受试者的另外10眼中对每个测厚法进行了一次测量,而检查员间的可重复性被评估为第一和第二位检查员的两次测量的绝对差。主要观察指标:通过3种方法进行的中央角膜厚度测量,由一名检查员进行的第一次和第二次测量的绝对差,由两名检查员进行的两次测量的绝对差以及相对变化量。结果:旋转Scheimpflug相机,扫描狭缝形貌和超声测厚仪对中央角膜厚度的平均测量分别为538 +/- 31.3微米,541 +/- 40.7微米和545 +/- 31.3微米。三种方法之间的测量结果无统计学差异(P = 0.569,重复测量方差分析)。旋转Scheimpflug相机和超声测厚法之间存在显着的线性相关性(r = 0.908,P <0.0001),旋转Scheimpflug相机和扫描狭缝形貌(r = 0.930,P <0.0001),超声测厚法和扫描狭缝形貌(r = 0.887,P <0.0001)。在这三种方法中,超声测厚法具有最大的内部检验者变异性,而扫描狭缝形貌具有最大的内部检验者变异性。在这三种方法中,检查者间可重复性存在相似的变化。结论:旋转的Scheimpflug相机,超声测厚仪和扫描狭缝形貌的平均角膜厚度与声学等效校正因子相当。 3种仪器的测量值彼此之间具有显着的线性相关性,并且所有方法均具有令人满意的测量重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号