首页> 外文期刊>International Journal of Greenhouse Gas Control >Injection operation and operational pressure-temperature monitoring at the CO2 storage pilot site Ketzin, Germany-Design, results, recommendations
【24h】

Injection operation and operational pressure-temperature monitoring at the CO2 storage pilot site Ketzin, Germany-Design, results, recommendations

机译:在德国二氧化碳储存试验场Ketzin进行注入操作和操作压力-温度监控-设计,结果,建议

获取原文
获取原文并翻译 | 示例
           

摘要

The Ketzin pilot site for geological storage of CO2 in the German Federal State of Brandenburg about 25 km west of Berlin is the only German CO2 storage site and has been the first European pilot site for on-shore storage of CO2 in saline aquifers. Continuous injection of CO2 started on June 30th, 2008, and a total of 61,396 t of CO2 have been injected by September 2012. The injected CO2 was predominantly food-grade with a purity >99.9%, only from May to June 2011, 1515 t CO2 from the Schwarze Pumpe oxyfuel pilot plant with a purity of >99.7% have been injected. The injection is accompanied by a comprehensive operational monitoring program. The program includes continuous measurements of flow rate, fill levels of intermediate storage tanks 1 and 2, outlet pressure and temperature for the injection plant, wellhead pressures (WHP) and casing pressures 1 and 2 for all wells, bottom hole pressure (BHP), bottom hole temperature (BHT) and distributed temperature sensing (DTS) along the injection tubing for the injection well Ktzi 201, BHP for the two observation wells Ktzi 202 (from March 2010 to October 2011) and Ktzi 200 (since October 2011), and above-zone pressure monitoring in shallow observation well P300. This operational pressure-temperature monitoring successfully ensured and proved a safe, smooth and reliable injection operation. A vital part of the operational P-T data comes from the downhole P-T measurements, which are recommended for any CO2 storage site. Without this downhole information, it would not have been possible to provide the complete picture of CO2 injection. The recommended downhole installation design of P-T tools distinguishes CO2 storage from the operational engineering of underground storage of natural gas, where BHP monitoring can be done via WHP recording. The DTS safety monitoring along the injection tubing supported typical operational processes as conditioning of the CO2 and improvement of injection rate and injection temperature and will be beneficial to any CO2 storage project. The above-zone pressure monitoring gives no hints to any hydraulic connection or CO2 leakage through or failure of the cap rock
机译:位于柏林以西25公里的德国联邦勃兰登堡州的Ketzin二氧化碳地质封存试点是德国唯一的二氧化碳封存点,并且是欧洲第一个在盐水层中陆上封存二氧化碳的试点。从2008年6月30日开始连续注入二氧化碳,到2012年9月,总共注入了61,396吨二氧化碳。注入的二氧化碳主要为食品级,纯度> 99.9%,仅从2011年5月至2011年6月为1515吨。来自Schwarze Pumpe含氧燃料中试厂的CO2的纯度大于99.7%。注入过程伴随着全面的运行监控程序。该程序包括连续测量流量,中间存储罐1和2的液位,注入设备的出口压力和温度,所有井的井口压力(WHP)和套管压力1和2,井底压力(BHP),注入井Ktzi 201,两个观测井Ktzi 202(从2010年3月至2011年10月)和Ktzi 200(自2011年10月起)沿注入管的井底温度(BHT)和分布温度感测(DTS),以及浅层观测井P300的区域以上压力监测。这种工作压力-温度监控成功地确保并证明了安全,平稳和可靠的喷射操作。作业P-T数据的重要部分来自井下P-T测量,建议将其用于任何CO2储存地点。没有这些井下信息,就不可能提供完整的二氧化碳注入图景。推荐的P-T工具井下安装设计可将二氧化碳存储与天然气地下存储的运营工程区分开来,在天然气地下存储可通过WHP记录进行监控。沿注入管的DTS安全监控支持典型的操作过程,例如调节CO2以及改善注入速率和注入温度,这将对任何CO2储存项目都有利。上面区域的压力监控没有暗示任何液压连接或盖石泄漏或二氧化碳泄漏的迹象

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号