...
首页> 外文期刊>International Journal of Climatology: A Journal of the Royal Meteorological Society >Carbon dioxide flux in the centre of ?ód?, Poland-analysis of a 2-year eddy covariance measurement data set
【24h】

Carbon dioxide flux in the centre of ?ód?, Poland-analysis of a 2-year eddy covariance measurement data set

机译:波兰“?d”中心的二氧化碳通量-一项为期两年的涡度协方差测量数据集的分析

获取原文
获取原文并翻译 | 示例

摘要

Continuous measurements of carbon dioxide turbulent flux FCO2 carried out with the eddy covariance method have been made in ?ód? since FCO2 July 2006. The measurement point (Lipowa Station) is located in the west part of the densely built-up city centre, where artificial surfaces clearly prevail over natural terrain. The measurement system includes a Kipp and Zonen's (Delft, Holland) CNR1 net radiometer, RMYoung (Traverse City, Michigamn, USA) 81000 sonic anemometer and Li-cor (Lincoln, Nebraska, USA) 7500 open path H2O/CO2 infrared gas analyser. Sensors are installed on the high tower 20 m above the roof of the building and 37 m above the ground, so the measurement height exceeded the urban canopy layer more than twice. The diurnal and annual variability of carbon dioxide flux for the period July 2006 to August 2008 is analysed in the article. The results show the characteristic features in diurnal and annual courses of FCO2. Independently from the season, positive (upward) fluxes of the order of 0-15 μmol m-2 s-1 prevail in the data. During the cold season, an increase in turbulent CO2 exchange is observed (FCO2 quite often exceeded 30 μmol m-2 s-1). This can be attributed to anthropogenic CO2 emissions, which are particularly strong in winter due to, among other things, mineral fuel combustion during domestic heating. The average monthly fluxes are positive in all seasons, which means that emission of CO2 in the surroundings of the measurement point prevails over its uptake. Apart from the season, the maximum flux occurred during the day and the minimum during the second part of the night. Wintertime monthly averaged fluxes are much higher than summertime ones. The observed increase in CO2 exchange during weekdays in comparison with weekends can be caused by the weekly rhythm of traffic in the surroundings of Lipowa Station.
机译:在?ód中已经连续测量了涡流协方差法对二氧化碳湍流FCO2的测量。自2006年7月FCO2起。测量点(Lipowa站)位于人口稠密的市中心的西部,那里的人工地面显然占据了整个自然地形。该测量系统包括Kipp and Zonen(荷兰代尔夫特)的CNR1净辐射计,RMYoung(美国密歇根州的特拉弗斯市)81000声波风速计和Li-cor(美国内布拉斯加州林肯)的7500开放式H2O / CO2红外气体分析仪。传感器安装在建筑物屋顶上方20 m和地面以上37 m的高塔上,因此测量高度超过城市雨棚层两倍以上。本文分析了2006年7月至2008年8月期间二氧化碳通量的日变化和年度变化。结果表明,FCO2的每日和年度课程具有特色。与季节无关,数据中的通量为0-15μmolm-2 s-1(向上)。在寒冷季节,观察到湍流CO2交换增加(FCO2经常超过30μmolm-2 s-1)。这可以归因于人为的CO2排放,其在冬天特别强烈,这尤其是由于家庭取暖期间矿物燃料的燃烧。在所有季节中,平均每月通量都是正值,这意味着测量点周围的二氧化碳排放量要高于其吸收量。除季节外,最大通量出现在白天,最小通量出现在夜晚的第二部分。冬季每月平均通量比夏季高得多。与周末相比,平日中观察到的二氧化碳交换量增加,可能是由于Lipowa站周围地区的每周交通节奏所致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号