Corneal and conjunctival sensitivity to air stimuli.

机译:角膜和结膜对空气刺激敏感。

获取原文
获取原文并翻译 | 示例
       

摘要

AIMS: To determine the repeatability of ocular surface sensitivity to mechanical stimulation using air stimuli and the effect of contact lens (CL) wear on sensitivity. METHODS: Repeatability: 14 subjects (24-39 years) participated. Mechanical sensitivity to warmed (34 degrees C) and ambient (20 degrees C) air was measured for the central cornea (CC), inferior cornea (IC), and inferior conjunctiva (ICON). Measurements were taken on 12 days; six morning and six afternoon measurements. Differences between sites, time of day, and stimulus temperature were evaluated. CL wear: 10 subjects (22-30 years) participated. Measurements were taken at the same time of day, either following no wear, wear of a CL of oxygen permeability [Dk] of 28x10(-9) [cm/s][ml O(2)/ml mm Hg] or wear of a CL of Dk 140x10(-9) [cm/s][ml O(2)/ml mm Hg]. Differences between sites and wear conditions were evaluated. RESULTS: Repeatability: Sensitivity varied between sites (p<0.01), time of day (p<0.05), and stimulus temperatures (p<0.01).There were no significant differences between days. Mean thresholds for eye temperature stimuli were; CC 64.4 (SD 28.6) ml/min; IC 84.6 (40.0) ml/min; ICON 120.6 (40.4) ml/min and for ambient temperature stimuli were CC 53.9 (16.0) ml/min, IC 59.0 (20.0) ml/min; ICON 72.6 (43.7) ml/min. CL wear: Sensitivity varied between sites and wear conditions (p<0.05). Conjunctival sensitivity was increased after wear of highly oxygen permeable CLs but unaffected by wear of low oxygen permeable CLs. CONCLUSIONS: The prototype gas aesthesiometer is able to repeatably measure ocular surface sensitivity and measurements are consistent with previously reported techniques.
机译:目的:确定眼表对使用空气刺激的机械刺激的敏感性的可重复性,以及隐形眼镜(CL)的佩戴对敏感性的影响。方法:重复性:14名受试者(24-39岁)参加。测量中央角膜(CC),下角膜(IC)和结膜下层(ICON)对热空气(34摄氏度)和环境空气(20摄氏度)的机械敏感性。在12天内进行测量;六个早晨和六个下午。评估了部位,一天中的时间和刺激温度之间的差异。 CL穿着:10位受试者(22-30岁)参加了比赛。在一天中的同一时间进行测量,要么不磨损,要么穿氧渗透率CL [Dk]为28x10(-9)[cm / s] [ml O(2)/ ml mm Hg]。 CL为Dk 140x10(-9)[cm / s] [ml O(2)/ ml mm Hg]。评估了部位和磨损条件之间的差异。结果:重复性:敏感性在部位(p <0.01),一天中的时间(p <0.05)和刺激温度(p <0.01)之间变化,各天之间无显着差异。眼睛温度刺激的平均阈值为: CC 64.4(SD 28.6)毫升/分钟; IC 84.6(40.0)毫升/分钟; ICON 120.6(40.4)ml / min,环境温度刺激为CC 53.9(16.0)ml / min,IC 59.0(20.0)ml / min; ICON 72.6(43.7)毫升/分钟CL磨损:灵敏度在部位和磨损条件之间有所不同(p <0.05)。佩戴高透氧性CL后结膜敏感性增加,但不受戴低透氧性CL的影响。结论:原型气体麻醉仪能够重复测量眼表敏感性,并且测量结果与先前报道的技术一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号