首页> 外文期刊>British journal of ophthalmology >Screening for retinopathy of prematurity (ROP) using wide-angle digital retinal photography by non-ophthalmologists: a systematic review
【24h】

Screening for retinopathy of prematurity (ROP) using wide-angle digital retinal photography by non-ophthalmologists: a systematic review

机译:非眼科医生使用广角数字视网膜摄影筛查早产儿视网膜病变(ROP):系统综述

获取原文
获取原文并翻译 | 示例
       

摘要

Retinopathy of prematurity (ROP) is one of the leading and preventable causes of blindness. The investigation of choice for diagnosing ROP is binocular indirect ophthalmoscope (BIO) done by ophthalmologists. Since the number of ophthalmologists available to do BIO examination is limited, especially in developing countries, there is a need for an alternate, cheap, reliable and feasible test. Telemedicine imaging with Digital Retinal Photography (DRP) is one such alternate diagnostic test which can be performed easily by non-ophthalmologists, with adequate training. Our objective was to conduct a systematic review to evaluate the accuracy of DRP performed by trained personnel (non-ophthalmologists) in diagnosing clinically significant ROP. Medline, EMBASE, CINAHL and Cochrane databases were searched independently by two authors. Eligible studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2, an evidence-based tool for the assessment of quality in systematic reviews of diagnostic accuracy studies. Six were included in the review (three prospective; N=120, three retrospective; N=579). Studies had methodological limitations on QUADAS-2. Because of the heterogeneity of studies, data could not be pooled to derive single-effect size estimates for sensitivity and specificity. The included studies reported sensitivity of 45.5-100% with the majority being more than 90%; specificity 61.7-99.8% with the majority being more than 90%, positive predictive value 61.5-96.6% and negative predictive value of 76.9-100% for diagnosing clinically significant ROP. We conclude that diagnostic accuracy of DRP must be established in prospective studies with adequate sample size where DRP is compared against the simultaneously performed BIO examination.
机译:早产儿视网膜病变(ROP)是导致失明的主要原因和可预防的原因之一。诊断ROP的首选方法是由眼科医生进行的双眼间接检眼镜(BIO)。由于可进行BIO检查的眼科医生的数量有限,尤其是在发展中国家,因此需要替代,廉价,可靠和可行的检查。使用数字视网膜摄影(DRP)进行的远程医学成像就是这样一种替代性诊断测试,非眼科医生可以在经过充分培训的情况下轻松进行。我们的目标是进行系统的评估,以评估由受过训练的人员(非眼科医生)在诊断具有临床意义的ROP时进行DRP的准确性。两位作者分别对Medline,EMBASE,CINAHL和Cochrane数据库进行了搜索。使用诊断准确性研究质量评估(QUADAS)-2评估合格的研究,QUADAS-2是基于证据的工具,用于对诊断准确性研究进行系统评价的质量评估。审查中包括六个(三个前瞻性; N = 120;三个回顾性; N = 579)。研究对QUADAS-2有方法上的限制。由于研究的异质性,无法汇总数据以得出敏感性和特异性的单效应量估计值。纳入的研究报告的敏感性为45.5-100%,大多数超过90%。诊断临床上显着的ROP的特异性为61.7-99.8%,大多数超过90%,阳性预测值为61.5-96.6%,阴性预测值为76.9-100%。我们得出的结论是,必须在前瞻性研究中以足够的样本量确定DRP的诊断准确性,并且将DRP与同时进行的BIO检查进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号