首页> 外文期刊>International Journal of Applied Engineering Research >Efficient Power factor improvement with SVC based on the PI controller under Load Fault in the smart grid
【24h】

Efficient Power factor improvement with SVC based on the PI controller under Load Fault in the smart grid

机译:智能电网负载故障下基于PI控制器的SVC的有效功率因数改善

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

in this paper, to improve the power quality and the efficiency, the power factor correction in the system is done by using SVC (Static Var Compensator) in load transient condition. The SVC is used TCR (thyristor controlled reactors) and TSC (thyristor switch capacitor). The system power factor is become constant by using SVC in the PCC (point of common coupling), where it is changed dramatically in different load conditions. To obtain the best power factor in the system, the PI controller is used to check the necessary reactive power by connecting the capacitance and the reactance to the PCC with TSC and TCR respectively. The simulation results are displayed with MATLAB/Simulink to verify the effectiveness of the proposed algorithm.
机译:为了提高电能质量和效率,本文通过在负载瞬态条件下使用SVC(静态无功补偿器)对系统中的功率因数进行校正。 SVC用于TCR(可控硅控制电抗器)和TSC(可控硅开关电容器)。通过在PCC中使用SVC(公共耦合点),系统功率因数变得恒定,在不同的负载条件下,功率因数会发生很大变化。为了在系统中获得最佳功率因数,PI控制器用于通过分别通过TSC和TCR将电容和电抗连接到PCC来检查必要的无功功率。仿真结果与MATLAB / Simulink一起显示,以验证所提出算法的有效性。