...
首页> 外文期刊>International archives of occupational and environmental health: Internationales Archiv fur Arbeits- und Umweltmedizin >Development of the fluorometric ELISA method for determination of alpha1-microglobulinuria in a cadmium-polluted area in Japan.
【24h】

Development of the fluorometric ELISA method for determination of alpha1-microglobulinuria in a cadmium-polluted area in Japan.

机译:开发用于在日本镉污染地区测定α1-微球蛋白尿症的荧光ELISA方法。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: To evaluate the usefulness of a newly developed fluorometric enzyme-linked immunosorbent assay (fluorometric ELISA) method for quantification of alpha1 -microglobulin (alpha1-m, protein HC) in an epidemiological study. METHODS: Urinary alpha1-m in 37 female inhabitants in a cadmium-polluted area, including seven cases with Itai-itai disease, and ten inhabitants in a non-polluted area in Japan were examined. The alpha1-m was measured by both the fluorometric ELISA and a commercially available enzyme immunoassay (EIA) method to evaluate correlation of the two measurements. Concentration of beta2-microglobulin (beta2-m) was also determined in the same samples. RESULTS: The detection limit of this method was 3 ng/ml or less of alpha1-m. A significant, high positive correlation was obtained between the alpha1-m concentrations measured with the fluorometric ELISA and that of EIA (r = 0.95, P < 0.0001). A significant association was also shown between the alpha1-m and beta2-m concentrations in the urine samples. The concentrations of urinary alphal-m of the inhabitants in the cadmium-polluted area (mean: 6.21 mg/l, 95% confidence interval (95% CI): 4.06-9.50 mg/l) were significantly higher than those of the reference area (mean: 2.19 mg/l, 95% CI: 1.90-2.67 mg/l). The urinary alpha1-m level of the Itai-itai patients was shown to be highest at 39.63 mg/l (95% CI: 28.27 55.55 mg/l). When the cut-off value of 10 mg/l was employed, alpha1-m had a sensitivity of 100% and specificity of 100% for Itai-itai disease. CONCLUSION: These results suggest that this fluorometric ELISA is a useful tool to determine urinary alpha1-m in the epidemiological survey of renal tubular dysfunction, especially in the cadmium-polluted area of Japan.
机译:目的:在流行病学研究中,评估一种新开发的荧光酶联免疫吸附测定法(荧光测定ELISA)用于定量α1-微球蛋白(α1-m,蛋白HC)的有效性。方法:检查了37名镉污染地区的女性居民中的尿液α1-m,其中包括7例伊泰伊塔伊病患者,以及日本无污染地区的10名居民。通过荧光ELISA和可商购的酶免疫法(EIA)方法测量alpha1-m,以评估两次测量的相关性。在相同样品中还测定了β2-微球蛋白(β2-m)的浓度。结果:该方法的检出限为3 ng / ml或更低的alpha1-m。用荧光ELISA法测得的α1-m浓度与EIA测得的α1-m浓度之间具有显着的正相关(r = 0.95,P <0.0001)。在尿液样本中的α1-m和β2-m浓度之间也显示出显着的关联。镉污染地区居民的尿中α1-m浓度(平均值:6.21 mg / l,95%置信区间(95%CI):4.06-9.50 mg / l)显着高于参考地区(平均值:2.19mg / l,95%CI:1.90-2.67mg / l)。 Itai-itai患者的尿中α1-m水平最高,为39.63 mg / l(95%CI:28.27 55.55 mg / l)。当使用10 mg / l的临界值时,alpha1-m对Itai-itai疾病的敏感性为100%,特异性为100%。结论:这些结果表明,这种荧光酶联免疫吸附测定法在肾小管功能障碍的流行病学调查中,尤其是在日本的镉污染地区,是测定尿中α1-m的有用工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号