首页> 外文期刊>International endodontic journal >Effect of plunger diameter on the push-out bond values of different root filling materials.
【24h】

Effect of plunger diameter on the push-out bond values of different root filling materials.

机译:柱塞直径对不同根部填充材料的推出粘结值的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

AIMS: To evaluate the effect of plunger diameter on the push-out bond strength of different root filling materials to root canal dentine. METHODOLOGY: Freshly extracted human incisors (n=90) were decoronated, and the root canals were enlarged with post drills. Prepared roots were placed into a custom alignment apparatus to embed the roots vertically within self-curing acrylic resin. The specimens were randomly assigned into three groups according to the root filling system used: gutta-percha/AH Plus; Resilon/Epiphany; and fibre-reinforced composite (FRC)/Duolink resin cement. After filling, the specimens were further subdivided according to the diameter of the plunger used to employ the debonding force: 0.75, 1 and 1.25 mm. Intra-radicular bond strength was measured using the push-out test at a cross-head speed of 1 mm min(-1) . The data were analysed statistically using Kruskal-Wallis test with Bonferroni correction at P = 0.05. RESULTS: Regardless of the plunger diameter, FRC yielded the highest bond strength, followed by gutta-percha and Resilon, respectively (P<0.001). In all groups, greater plunger diameter resulted in an apparent increased bond strength, but the differences were only significant in the FRC group, with the 1.25-mm plunger generating higher debonding values compared with that of its 0.75- and 1-mm versions (P<0.001). In the gutta-percha and Resilon groups, the majority of specimens had adhesive failures. Roots filled with FRC exhibited more cohesive failures than those of the other test groups. CONCLUSIONS: Different plunger diameters are associated with significantly different intra-radicular push-out bond strengths of root filling systems.
机译:目的:评估柱塞直径对不同牙根充填材料对牙根管牙本质推出强度的影响。方法:对刚摘下的人门牙(n = 90)进行脱毛,并用牙轮钻扩大根管。将准备好的根部放入定制的对齐设备中,以将根部垂直嵌入自固化丙烯酸树脂中。根据所使用的根部填充系统将标本随机分为三组:gutta-percha / AH Plus; Resilon /主显节;以及纤维增强复合材料(FRC)/ Duolink树脂水泥。填充后,根据用于施加脱粘力的柱塞直径将样品进一步细分:0.75、1和1.25 mm。使用顶出试验在1 mm min(-1)的十字头速度下测量了射线内粘合强度。使用Kruskal-Wallis检验对数据进行统计学分析,Bonferroni校正为P = 0.05。结果:无论柱塞直径如何,FRC产生的粘结强度最高,其次分别为胶状胶和Resilon(P <0.001)。在所有组中,更大的柱塞直径导致粘结强度明显增加,但差异仅在FRC组中显着,与0.75mm和1mm版本相比,1.25mm柱塞产生更高的脱胶值(P <0.001)。在牙胶和Resilon组中,大多数标本都发生了粘合破坏。与其他测试组相比,充满FRC的根表现出更多的内聚破坏。结论:不同的柱塞直径与根部填充系统的显着不同的放射内推挤结合强度有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号