OBJECTIVES: To establish the levels of pressure used to perform tracheal suction (TS) and if they are affected by having a manometer visible in the suction circuit. DESIGN: A bench test evaluation of simulated tracheal suction. SETTING: Physiotherapy department of a major teaching hospital in Melbourne, Australia. PARTICIPANTS: Sixty-four nurses and physiotherapists who regularly apply TS to patients in the intensive care units of this hospital. INTERVENTIONS: All subjects used both circuit A (without a visible manometer) and B (with a visible manometer) in a predetermined random order. For both, subjects adjusted the suction control tap to where they said a safe and effective pressure (set pressure) was delivered and then occluded the suction catheter as though suctioning (applied pressure). Subjects then completed a questionnaire on their current TS practise. MEASUREMENTS and results: All set pressures (mean = 228.57 mmHg) and all applied pressures (mean = 359. 52 mmHg) were significantly higher (P <.001) when compared to the expected pressures (mean = 135 mmHg). Pressures set without a visible manometer (circuit A) were significantly higher (P <.05) than those using a visible manometer (circuit B) but the applied pressures were not significantly different (P =.166). Neither the investigator (P =.618) or the test order (P =.167) had a significant effect on the outcome. Questionnaire results showed 31 % of subjects considered 100-170 mmHg a safe and effective suction pressure whilst none reported using an objective means of measuring pressure. CONCLUSION: All pressures in both circuits were significantly higher than those recommended as safe in the literature. In addition, pressures were unaffected by the inclusion of a visible manometer in the suction circuit.
机译:目的:建立用于执行气管抽吸(TS)的压力水平,以及压力水平是否受抽吸回路中可见压力计的影响。设计:模拟气管抽吸的台架试验评估。地点:澳大利亚墨尔本一家主要教学医院的理疗科。参与者:六十四名护士和理疗师定期向该医院的重症监护病房的患者应用TS。干预:所有受试者均以预定的随机顺序使用回路A(无可见压力表)和回路B(有可见压力表)。对于这两种方法,受试者都将抽吸控制抽头调整到他们说的安全和有效压力(设定压力)已输送到的位置,然后像吸引(施加压力)一样阻塞抽吸导管。受试者随后完成了有关其当前TS实践的问卷调查。测量和结果:与预期压力(平均值= 135 mmHg)相比,所有设定压力(平均值= 228.57 mmHg)和所有施加压力(平均值= 359. 52 mmHg)均显着更高(P <.001)。没有可见压力表(电路A)的设定压力(P <.05)显着高于使用可见压力表(电路B)的设定压力(P = .166)。研究者(P = .618)或测试订单(P = .167)均未对结果产生重大影响。问卷调查结果显示,有31%的受试者认为100-170 mmHg是安全有效的抽吸压力,而没有人使用客观的压力测量方法进行报告。结论:两个回路中的所有压力均明显高于文献中推荐的安全性。此外,在吸入回路中加入可见压力计不会影响压力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号