首页> 外文期刊>Instruments and Experimental Techniques >A method for determining the maximal size of through pores of ceramics from the temperature of the water crystallization onset
【24h】

A method for determining the maximal size of through pores of ceramics from the temperature of the water crystallization onset

机译:从水结晶开始温度确定陶瓷通孔最大尺寸的方法

获取原文
获取原文并翻译 | 示例
           

摘要

A new method for determining the maximal size of through channels of porous materials from the temperature of the water crystallization onset (crystallization-onset method) is proposed. The comparative measurements of sizes of through pores of ceramic filters by this method and by the method of determining the point of bubble growth are performed in accordance with GOST (State Standard) 50516-93. The correlation dependence between the overshoot pressure drop of the first bubble and the temperature of the water crystallization onset in the pore space of a ceramic filter is plotted.
机译:提出了一种从水的结晶起始温度确定多孔材料通过通道最大尺寸的新方法(结晶起始方法)。通过该方法和通过确定气泡生长点的方法,根据GOST(国家标准)50516-93进行陶瓷过滤器的通孔的尺寸的比较测量。绘制了第一气泡的过冲压力降与陶瓷过滤器的孔空间中水结晶开始温度之间的相关性。