...
首页> 外文期刊>American journal of human biology: the official journal of the Human Biology Council >Comparison of body fat estimates using 3D digital laser scans, direct manual anthropometry, and DXA in men.
【24h】

Comparison of body fat estimates using 3D digital laser scans, direct manual anthropometry, and DXA in men.

机译:使用3D数字激光扫描,直接手动人体测量法和DXA对男性的体内脂肪估算值进行比较。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVES: The purpose of this study was to assess the feasibility of utilizing three dimensional whole body laser surface scanning (3DS) to obtain specific anthropometric measurements to estimate percent body fat (BF). METHODS: Percent BF estimates from 37 male volunteers, of age 18-62 yr, were determined by inputting manual anthropometric (MA) and 3DS anthropometric measurements into the current Army BF prediction equation for males. The results were compared with each other and to BF values from Dual Energy X-ray Absorptiometry (DXA), employed as a reference method. RESULTS: Mean percent BF estimates (+/-SD) derived from MA, 3DS and from DXA were 18.4(+/-3.8), 18.8(+/-3.9), and 18.9(+/-4.7), respectively. Analysis of Variance tests revealed no statistical difference between the mean values. Correlation analysis comparing MA and 3DS derived percent BF estimates to each other and to those measured by DXA revealed moderate to strong Pearson correlation coefficients (r), small to moderate standard errors of the estimate (SEE), and were statistically significant (p < 0.05). CONCLUSIONS: Correlation coefficients and SEE results for this sample were: (1) DXA vs 3DS; r = 0.74, SEE = 3.2, (2) MA vs DXA; r = 0.82, SEE = 2.8, and (3) MA vs 3DS; r = 0.96, SEE = 1.0. Lin's concordance analysis, including Bland-Altman limits of agreement (LOA), revealed statistically significant measurement agreement among the three measurement modalities (p < 0.05). The application of 3DS scanning to estimate percent BF from commonly used anthropometric measurements are in close agreement with BF estimates derived from analogous MA measurements and from DXA scanning.
机译:目的:本研究的目的是评估利用三维全身激光表面扫描(3DS)获得特定人体测量值以估算体内脂肪(BF)的可行性。方法:通过将人工人体测量法(MA)和3DS人体测量法输入当前的陆军男性BF预测方程中,来确定37位18-62岁男性志愿者的BF估计百分比。将结果相互比较,并与双能量X射线吸收法(DXA)的BF值进行比较,该值用作参考方法。结果:从MA,3DS和DXA得出的平均BF估计百分率(+/- SD)分别为18.4(+/- 3.8),18.8(+/- 3.9)和18.9(+/- 4.7)。方差检验的分析表明,平均值之间无统计学差异。将MA和3DS得出的BF估计值彼此之间以及与DXA测得的百分比进行相关性分析,结果显示中度到强的Pearson相关系数(r),估计值的中小标准误差(SEE),具有统计学意义(p <0.05 )。结论:该样本的相关系数和SEE结果为:(1)DXA vs 3DS; r = 0.74,SEE = 3.2,(2)MA对DXA; r = 0.82,SEE = 2.8,以及(3)MA vs 3DS; r = 0.96,SEE = 1.0。 Lin的一致性分析(包括Bland-Altman协议限制(LOA))揭示了三种测量方式之间具有统计学意义的测量一致性(p <0.05)。使用3DS扫描从常用的人体测量学估计BF百分比与从类似的MA测量和DXA扫描得出的BF估计非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号