Uranyl ion selective electrode based on thenoyl trifluor acetone (TTA) incorporated into a polyvinyl chloride (PVC) membrane has been developed where dibutyl phthalate and sodium tetraphenyl borate have been used as plasticizer and anion excluder respectively.The PVC membrane containing the active ionophore.TTA,and the other ingredients has been directly cast on a graphite electrode.The electrode shows near Nernstian response to UO_2~(2+) in the concentration range of 10~(-3) to 10~(-6) mol L~(-1) with an average slope of 30 mV/decade.Alkali and alkaline earth metal ions do not interfere with the determination of uranyl ion.Interference of transition metal ions and Th(IV) is eliminated with EDTA.
机译:已经开发出了基于壬基三氟丙酮(TTA)并入聚氯乙烯(PVC)膜中的铀酰离子选择电极,其中分别使用邻苯二甲酸二丁酯和四苯基硼酸钠作为增塑剂和阴离子排斥剂。然后将其他成分直接浇铸在石墨电极上。该电极在10〜(-3)到10〜(-6)mol L〜(-)的浓度范围内对UO_2〜(2+)表现出接近能斯特的响应。 1)平均斜率为30 mV /十年,碱金属和碱土金属离子不会干扰铀酰离子的测定,EDTA消除了过渡金属离子和Th(IV)的干扰。