Enumeration of viable counts in raw milk using the automated fluorescence microscopic method.

机译:使用自动荧光显微镜方法对生乳中的活菌计数进行计数。

获取原文
获取原文并翻译 | 示例
           

摘要

An automated fluorescence microscopy method developed for the measurement of viable bacterial counts was applied to the detection and enumeration of viable bacteria in milk. In the automated analysis of viable bacteria, bacterial cells were recovered from milk after treatments with EDTA and Triton X-100, stained with 6-CFDA, and the stained cells were counted with the automated microscopy method. Salmonella enteritidis expressing the enhanced green fluorescent protein (S. enteritidis-EGFP) was used to elucidate the relationship between the fluorescent bacterial counts by the automated microscopy method and the viable counts by the conventional plating method. A high correlation coefficient (r2=0.97) was obtained for the relationship between the counts by the microscopy method and those by the plating method. When S. enteritidis-EGFP was recovered from sterile milk after treatments with EDTA and Triton X-100, the correlation coefficient was r2=0.91. Viable counts by the plating method and the counts of 6-CFDA stained bacterial cells by the automated microscopy method were determined for various raw milk samples. 37 raw milk samples were measured and the correlation coefficient was r2=0.73. It is suggested that the developed automated fluorescence microscopy method could also be used to detect specific enteropathogenic bacteria by using specific antibodies labelled with fluorescent dyes..
机译:为检测活菌计数而开发的自动荧光显微镜方法被应用于牛奶中活菌的检测和计数。在活菌的自动分析中,用EDTA和Triton X-100处理后,从牛奶中回收细菌细胞,用6-CFDA染色,然后用自动显微镜法对染色的细胞进行计数。表达增强的绿色荧光蛋白的肠炎沙门氏菌(S. enteritidis-EGFP)用于阐明自动显微镜法检测的荧光细菌计数与常规接种法检测的活菌计数之间的关系。对于通过显微镜法和通过电镀法的计数之间的关系,获得了高相关系数(r2 = 0.97)。当用EDTA和Triton X-100处理后从无菌乳中回收肠炎链球菌-EGFP时,相关系数为r2 = 0.91。对于各种原料乳样品,通过平板法确定了活菌计数,并通过自动显微镜法确定了6-CFDA染色细菌细胞的计数。测量了37个原奶样品,相关系数为r2 = 0.73。建议通过使用荧光染料标记的特异性抗体,开发的自动荧光显微镜方法也可用于检测特定的肠致病细菌。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号