首页> 外文期刊>Neural computing & applications >Characterization of electrical 1-phase transformer parameters with guaranteed hotspot temperature and aging using an improved dwarf mongoose optimizer
【24h】

Characterization of electrical 1-phase transformer parameters with guaranteed hotspot temperature and aging using an improved dwarf mongoose optimizer

机译:Characterization of electrical 1-phase transformer parameters with guaranteed hotspot temperature and aging using an improved dwarf mongoose optimizer

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Parameters identification of Electric Power Transformer (EPT) models is significant for the steady and consistent operation of the power systems. The nonlinear and multimodal natures of EPT models make it challenging to optimally estimate the EPT's parameters. Therefore, this work presents an improved Dwarf Mongoose Optimization Algorithm (IDMOA) to identify unknown parameters of the EPT model (1-phase transformer) and to appraise transformer aging trend under hottest temperatures. The IDMOA employs a population of solutions to get as much information as possible within the search space through generating different solution' vectors. Furthermore, the Nelder-Mead Simplex method is incorporated to efficiently promote the neighborhood searching with the aim to find a high-quality solution during the iterative process. At initial stage, power transformer electrical equivalent extraction parameters are expressed in terms of the fitness function and its corresponding operating inequality restrictions. In this sense, the sum of absolute errors (SAEs) among numerous factors from nameplate data of transformers is to be minimized. The proposed IDMOA is demonstrated on two transformer ratings as 4 kVA and 15 kVA, respectively. Moreover, the outcomes of the IDMOA are compared with other recent challenging optimization methods. It can be realized that the lowest minimum values of SAEs compared to the others which are 3.3512e-2 and 1.1200e-5 for 15 kVA and 4 kVA cases, respectively. For more assessment for the proposed optimizer, the extracted parameters are utilized to evaluate the transformer aging considering the transformer hottest temperature compared with effect of the actual parameters following the IEEE Std C57.91 procedures. It is proved that the results are guaranteed, and the transformer per unit nominal life is 1.00 at less than 110 degrees C as per the later-mentioned standard.
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号