首页> 外文期刊>Atomic Spectroscopy >Direct and simultaneous determination of As, Cu, and Pb in Brazilian sugar cane spirits by graphite furnace AAS using Tungsten permanent modifier with Co-injection of Pd/Mg(NO3)(2)
【24h】

Direct and simultaneous determination of As, Cu, and Pb in Brazilian sugar cane spirits by graphite furnace AAS using Tungsten permanent modifier with Co-injection of Pd/Mg(NO3)(2)

机译:钨永久性改性剂-石墨炉原子吸收光谱法同时进样Pd / Mg(NO3)(2)同时直接测定巴西甘蔗油中的As,Cu和Pb

获取原文
获取原文并翻译 | 示例

摘要

A method was developed using the multi-element graphite furnace atomic absorption spectrometry technique for the direct and simultaneous determination of As, Cu, and Pb in Brazilian sugar cane spirit (cachaqa) samples. Also employed was the end-capped transversely heated graphite atomizer (THGA) with platforms pre-treated with W permanent modifier and co-injection of Pd/Mg(NO3)(2). Pyrolysis and atomization temperature curves were established in a cachaqa medium (1+1; v/v) containing 0.2% (v/v) HNO3 and spiked with 20 mu g L-1 As and Pb and 200 mu g L-1 Cu. The effect of the concentration of major elements usually present in cachaqa matrices (Ca, Mg, Na, and K) and ethanol on the absorbance of As, Cu, and Pb was investigated. Analytical working solutions of As, Cu, and Pb were prepared in 10% (v/v) ethanol plus 5.0 mg L-1 Ca, Mg, Na, and K. Acidified to 0.2% (v/v) HNO3, these solutions were suitable to build calibration curves by matrix matching. The proposed method was applied to the simultaneous determination of As, Cu, and Pb in commercial sugar cane spirits. The characteristic mass for the simultaneous determination was 16 pg As, 119 pg Cu, and 28 pg Pb. The pretreated tube lifetime was about 450 firings. The limit of detection (LOD) was 0.6 mu g L-1 As, 9.2 mu g L-1 Cu, and 0.3 pig L-1 Pb. The found concentrations varied from 0.81 to 4.28 mu g L-1 As, 0.28 to 3.82 mg L-1 Cu and 0.82 to 518 mu g L-1 Pb. The recoveries of the spiked samples varied from 94-112% (As), 97-111% (Cu), and 95-101% (Pb). The relative standard deviation (n=12) was 6.9%, 7.4%, and 7.7% for As, Cu, and Pb, respectively, present in a sample at 0.87 mu g L-1, 0.81 mg L-1, and 38.9 mu g L-1 concentrations.
机译:开发了一种使用多元素石墨炉原子吸收光谱技术直接和同时测定巴西甘蔗酒精(cachaqa)样品中As,Cu和Pb的方法。还使用了端盖的横向加热石墨雾化器(THGA),其平台经W永久改性剂预处理,并共注入Pd / Mg(NO3)(2)。在含有0.2%(v / v)HNO3的掺加了20μg L-1 As和Pb以及200μgL-1 Cu的cachaqa介质(1 + 1; v / v)中建立了热解和雾化温度曲线。研究了通常存在于cachaqa矩阵(Ca,Mg,Na和K)和乙醇中的主要元素的浓度对As,Cu和Pb吸收的影响。在10%(v / v)乙醇和5.0 mg L-1 Ca,Mg,Na和K中配制As,Cu和Pb的分析工作溶液。酸化至0.2%(v / v)HNO3,适用于通过矩阵匹配建立校正曲线。该方法可同时测定市售甘蔗酒中的砷,铜和铅。同时测定的特征质量为16 pg As,119 pg Cu和28 pg Pb。预处理管的寿命约为450次点火。检出限(LOD)为0.6μg L-1 As,9.2μg L-1 Cu和0.3猪L-1 Pb。所发现的浓度范围从0.81至4.28微克L-1 As,0.28至3.82毫克L-1 Cu和0.82至518微克L-1 Pb。加标样品的回收率在94-112%(As),97-111%(Cu)和95-101%(Pb)之间。样品中As,Cu和Pb的相对标准偏差(n = 12)分别为6.9%,7.4%和7.7%,分别为0.87μgL-1、0.81 mg L-1和38.9μg g L-1浓度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号