...
首页> 外文期刊>Spectrochimica Acta, Part B. Atomic Spectroscopy >Evaluation of Bi as internal standard to minimize matrix effects on the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru permanent modifier with co-injection of Pd/Mg(NO3)(2)
【24h】

Evaluation of Bi as internal standard to minimize matrix effects on the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru permanent modifier with co-injection of Pd/Mg(NO3)(2)

机译:使用Ru永久性改性剂与Pd / Mg(NO3)(2)共注入石墨炉原子吸收光谱法评估Bi作为内标,以最大程度地减少基质对醋中Pb直接测定的影响

获取原文
获取原文并翻译 | 示例

摘要

Bismuth was evaluated as an internal standard for the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru as a permanent modifier with co-injection of Pd/Mg(NO3)(2). The correlation coefficient of the graph plotted from the non-nalized absorbance signals of Bi versus Pb was r=0.989. Matrix effects were evaluated by analyzing the slope ratios between the analytical curve, and analytical curves obtained from Pb additions in red and white wine vinegar obtained from reference solutions prepared in 0.2% (v/v) HNO3, samples. The calculated ratios were around 1.04 and 1.02 for analytical curves established applying an internal standard and 1.3 and 1.5 for analvtical curves without. Analytical curves in the 2.5-15 pg L-1 Pb concentration interval were established using the ratio Pb absorbance to Bi absorbance versus analvte concentration, and typical linear correlations of r=0.999 were obtained. The proposed method was applied for direct determination of Pb in 18 commercial vinegar samples and the Pb concentration varied from 2.6 to 31 pg L-1. Results were in agreement at a 95% confidence level (paired t-test) with those obtained for digested samples. Recoveries of Pb added to vinegars varied from 96 to 108% with and from 72 to 86% without an internal standard. Two water standard reference materials diluted in vinegar sample were also analyzed and results were in agreement with certified values at a 95% confidence level. The characteristic mass was 40 pg Pb and the useful lifetime of the tube was around 1600 firings. The limit of detection was 0.3 mu g L-1 and the relative standard deviation was <= 3.8% and <= 8.3% (n = 12) for a sample containing, 10 mu L-1 Pb with and without internal standard, respectively. (C) 2007 Elsevier B.V. All rights reserved.
机译:铋被评定为内标,用于通过石墨炉原子吸收光谱法同时使用Ru作为永久性改性剂和共注入Pd / Mg(NO3)(2)来直接测定醋中的Pb。从Bi和Pb的非归一化吸光度信号绘制的图的相关系数为r = 0.989。通过分析分析曲线之间的斜率,以及从在0.2%(v / v)HNO3中制备的参考溶液中获得的红葡萄酒和白葡萄酒醋中Pb的添加所获得的分析曲线,评估基体效应。对于使用内标建立的分析曲线,计算比率约为1.04和1.02,对于不使用内标的分析曲线,计算比率为1.3和1.5。使用铅与铋的吸光度比对苯甲酸浓度的比率建立了2.5-15 pg L-1 Pb浓度区间的分析曲线,并且得到了r = 0.999的典型线性相关性。该方法用于直接测定18种商业食醋样品中的Pb,其Pb浓度范围为2.6至31 pg L-1。结果与消化后的样品在95%的置信度(配对t检验)上一致。添加到醋中的铅的回收率在不使用内标的情况下为96%至108%,在不使用内标的情况下为72%至86%。还分析了两种在醋样品中稀释的水标准参考物质,其结果与95%置信度下的认证值相符。特征质量为40 pg Pb,该管的使用寿命约为1600次烧成。检出限为0.3μg L-1,相对标准偏差分别为<= 3.8%和<= 8.3%(n = 12),其中包含10μLL-1 Pb(有和没有内标)。 (C)2007 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号