首页> 外文期刊>American Industrial Hygiene Association Journal >Effects of a novel ice-cooling technique on work in protective clothing at 28 degrees C, 23 degrees C, and 18 degrees C WBGTs.
【24h】

Effects of a novel ice-cooling technique on work in protective clothing at 28 degrees C, 23 degrees C, and 18 degrees C WBGTs.

机译:新型冰冷却技术对28摄氏度,23摄氏度和18摄氏度WBGT防护服工作的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

This study tested a new ice cooling system that permits ice cooling system recharge without personal protective clothing removal. Six male volunteers (22.1 +/- 1.2 years) underwent tests with the new ice cooling system (COOL) and without (NOCL) at a moderate work rate (450 W) in three environments of 28, 23, and 18 +/- 1 degrees C wet bulb globe temperature. Walks at 28 degrees C were carried out first with NOCL and COOL counterbalanced, then test order and environment were counterbalanced. At 28 degrees C, mean work time in COOL significantly increased by 37.5 min (188%) over NOCL (p < 0.05). At 23 degrees C mean work time in COOL was significantly increased by 44.3 min (171%) compared with NOCL (p < 0.05). Mean work times at 18 degrees C were not significantly different, although all subjects completed the 120 minutes of work in COOL compared with a mean work time of 109 +/- 20 min for NOCL. During rest, mean reductions in rectal temperature were significantly greater in COOL than NOCL (p < 0.05) at 28 and 23 degrees C. Mean heart rate calculated for the same point in both treatments was significantly lower for COOL at 28, 23, and 18 degrees C (p < 0.05). Thermal comfort rating was significantly different at 18 and 23 degrees C (p < 0.05). This new design seemed to provide comparable cooling to conventional vests and also provides greater practicality for field use. Even in experimental form the suit demonstrated increased productivity due to extended tolerance time.
机译:这项研究测试了一种新的冰冷却系统,该系统可以在不移除个人防护服的情况下对冰冷却系统进行充电。六名男性志愿者(22.1 +/- 1.2岁)在28、23和18 +/- 1的三种环境中以中等工作速率(450 W)进行了使用新冰冷却系统(COOL)和不使用(NOCL)的测试。摄氏度的湿球温度。首先在NOCL和COOL平衡的情况下在28摄氏度下行走,然后平衡测试顺序和环境。在28摄氏度下,COOL中的平均工作时间比NOCL显着增加了37.5分钟(188%)(p <0.05)。与NOCL相比,在23摄氏度时,COOL中的平均工作时间显着增加了44.3分钟(171%)。尽管所有受试者在COOL中完成了120分钟的工作,而NOCL的平均工作时间为109 +/- 20分钟,但在18摄氏度下的平均工作时间并没有显着差异。在休息期间,在28和23摄氏度时,COOL的平均直肠温度降低明显大于NOCL(p <0.05)。两种治疗中同一点计算的平均心率在28、23和18时均明显低于COOL摄氏度(p <0.05)。在18和23摄氏度时,热舒适性等级显着不同(p <0.05)。这种新设计似乎可以提供与传统背心类似的冷却效果,并且还为现场使用提供了更大的实用性。即使以实验形式,由于延长了耐受时间,该套装仍显示出提高的生产率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号