...
首页> 外文期刊>Arthroscopy: the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association >Comparison of in vitro and in vivo complement activation by metal and bioabsorbable screws used in anterior cruciate ligament reconstruction.
【24h】

Comparison of in vitro and in vivo complement activation by metal and bioabsorbable screws used in anterior cruciate ligament reconstruction.

机译:比较用于前十字韧带重建的金属和生物可吸收螺钉在体外和体内的补体激活。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: The purpose of the study was to evaluate the biocompatibility of polylactide (PLLA) screws in comparison with standard metal screws for fixation of the patellar tendon graft in human anterior cruciate ligament (ACL) reconstruction. METHODS: A total of 41 patients (22 women and 19 men) were prospectively randomized for the use of metal interference screws (20 patients) or biologically resorbable PLLA screws from Linvatec, Largo, FL (21 patients). Average age at the time of surgery was 26 years (15 to 51 y). Synovial fluid and plasma were collected preoperatively and after 6 weeks in both groups. Plasma was analyzed for C5a and synovial fluid, as well as for terminal SC5b-9 complement complex (TCC) and interleukin (IL)-8. At 1 year after surgery, serum was incubated with metal, PLLA, and no screws; this was followed by analysis of C5a after 1 and 6 hours of incubation. Inflammatory mediators were measured through enzyme-linked immunosorbent assay (ELISA). RESULTS: In the BioScrew group, 4 patient samples showed high C5a concentration in synovial fluid after 6 weeks, but no statistically significant difference was observed between the 2 groups (P = .11). One patient in the BioScrew group had a high TCC value after 6 weeks, but no statistically significant difference was seen between the 2 groups (P = .20). In the in vitro study, no increased C5a generation was observed in sera incubated with a BioScrew or a metal screw compared with controls. CONCLUSIONS: No statistically significant difference was observed between the BioScrew and metal screw groups concerning C5a, TCC, and IL-8 formation. However, some patients in the BioScrew group showed elevated values. LEVEL OF EVIDENCE: Level II, prospective randomized trial.
机译:目的:本研究的目的是评估聚乳酸(PLLA)螺钉与标准金属螺钉在人前十字韧带(ACL)重建中固定tell骨肌腱的生物相容性。方法:前瞻性将41例患者(22例女性和19例男性)随机分配,以使用金属干涉螺钉(20例)或可生物吸收的PLLA螺钉(21位患者)。手术时的平均年龄为26岁(15至51岁)。两组均于术前及术后6周收集滑液和血浆。分析血浆中的C5a和滑液,以及末端SC5b-9补体复合物(TCC)和白介素(IL)-8。手术后1年,将血清与金属,PLLA和无螺丝孵育;孵育1和6小时后,分析C5a。通过酶联免疫吸附测定(ELISA)测量炎症介质。结果:在BioScrew组中,在6周后有4例患者样本显示滑液中C5a浓度较高,但两组之间未观察到统计学上的显着性差异(P = .11)。 BioScrew组中的一名患者在6周后具有较高的TCC值,但两组之间无统计学差异(P = 0.20)。在体外研究中,与对照相比,在用BioScrew或金属螺丝孵育的血清中未观察到C5a产生增加。结论:BioScrew组和金属螺钉组之间在C5a,TCC和IL-8形成方面没有统计学上的显着差异。但是,BioScrew组中的某些患者显示出较高的值。证据水平:II级,前瞻性随机试验。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号