首页> 外文期刊>Arthroscopy: the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association >Comparison of mechanical stability in double-row rotator cuff repairs between a knotless transtendon construct versus the addition of medial knots.
【24h】

Comparison of mechanical stability in double-row rotator cuff repairs between a knotless transtendon construct versus the addition of medial knots.

机译:无结跨腱结构与增加内侧结之间的双排肩袖修复中的机械稳定性比较。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: Our purpose was to investigate the importance of medial-row knot tying to mechanical stability in a double-row rotator cuff repair by comparing a knotless construct with transtendon anchor passage versus a similar construct implementing medial knots. METHODS: A standard defect was created in the infraspinatus tendons of 14 bovine humeri. All defects were repaired with 2 medial and 2 lateral anchors (SutureCross System; KFx Medical, Carlsbad, CA). The medial anchors were either placed by transtendon passage in a knotless construct or placed directly into bone with needle passage of suture to create bursal-sided knots medially. Constructs were subjected to a cyclic loading protocol and then loaded to failure. RESULTS: The medially knotted constructs had a statistically higher stiffness at both the initial and final cycles (P < .001 and P < .001, respectively) and a lower displacement during cyclic loading (P < .02). There were strong trends toward decreased gauge displacement (P = .12) and decreased cycles to 3 mm of displacement (P = .07) in the medially knotted group. Maximal yield strength was greater in the medially knotted group (350 +/- 270 N v 650 +/- 530 N), although this was not found to be statistically significant (P = .5). CONCLUSIONS: Our data suggest that creation of medial knots increases construct stiffness and stability in arthroscopic double-row cuff repair. This is likely because of increased load transfer to the lateral anchor and suture-tendon interface in the knotless construct. CLINICAL RELEVANCE: Medial knots create increased mechanical stability that theoretically may improve rotator cuff healing. This mechanical advantage must be weighed against surgical efficiency, with consideration given to factors such as tissue quality.
机译:目的:我们的目的是通过比较无齿构造和跨腱锚定通道与类似实施内侧结的类似构造,研究在双排肩袖修复中内侧成行结对机械稳定性的重要性。方法:在14头肱骨肱骨下肌腱中创建了标准缺损。所有缺陷均使用2个内侧和2个外侧锚钉(SutureCross System; KFx Medical,卡尔斯巴德,加利福尼亚)修复。内侧锚定物通过跨腱通道放置在无结结构中,或通过缝合线通过针直接放置在骨骼中,以在内侧形成法氏囊侧结。对构建体进行循环加载协议,然后将其加载到失败。结果:内侧打结的结构在初始和最终循环中均具有统计学上较高的刚度(分别为P <.001和P <.001),而在循环载荷下具有较低的位移(P <.02)。在内侧打结的组中,有一个趋势是减少标距位移(P = .12)和减少周期至3 mm位移(P = .07)。在中间打结的组中,最大屈服强度更大(350 +/- 270 N v 650 +/- 530 N),尽管没有统计学意义(P = 0.5)。结论:我们的数据表明,内侧节的形成增加了关节镜双排袖套修复中的结构刚度和稳定性。这可能是由于增加了向无结构造中的侧向锚固和缝合线-肌腱界面的载荷传递。临床意义:内侧结增加了机械稳定性,从理论上讲可以改善肩袖的愈合。必须考虑诸如组织质量等因素,权衡这种机械优势和手术效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号