首页> 外文期刊>Arthroscopy: the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association >Comparison of initial fixation properties of sutured and nonsutured soft tissue anterior cruciate ligament grafts with femoral cross-pin fixation.
【24h】

Comparison of initial fixation properties of sutured and nonsutured soft tissue anterior cruciate ligament grafts with femoral cross-pin fixation.

机译:股骨交叉钉固定法比较缝合线和未缝合的软组织前交叉韧带移植物的初始固定特性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To determine whether or not suturing a soft tissue graft in a whipstitch fashion is an essential procedure in order to ensure sufficient initial fixation strength of the cross-pin fixation technique in anterior cruciate ligament reconstruction. METHODS: Porcine digital extensor tendons were used as 4-stranded soft tissue grafts. Specimens were fixated within 52 porcine femoral bone tunnels using a cross-pin fixation technique (RigidFix; Ethicon, Norderstedt, Germany). In group I (n = 28), the looped-over part of the grafts was sutured using a whipstitch technique; in group II (n = 28) the grafts were not sutured. Initial fixation properties were determined using either a single cycle load to failure protocol or a dynamic loading protocol, submitting the graft to 1,000 cycles of flexion-extension loading between 0 degrees and 90 degrees , followed by ultimate loading to failure. The graft-pin interaction and the graft-tunnel interface was histomorphologically visualized in unloaded and dynamically loaded grafts. RESULTS: After dynamic loading, the residual displacement in sutured grafts was lower when compared to nonsutured grafts. The ultimate failure loads were significantly lower in nonsutured grafts when compared to sutured grafts after dynamic loading. The histomorphologic analysis demonstrated intratunnel displacement of nonsutured grafts after dynamic loading, while sutured grafts remained in situ. In cases where the cross-pins had not threaded the tendon loops, sutured grafts provided higher fixation strength and less graft displacement. CONCLUSIONS: The results of the present study suggest that suturing the looped-over portion of a quadruple tendon graft provides superior biomechanical graft fixation properties when compared to nonsutured grafts when using the femoral cross-pin fixation technique. CLINICAL RELEVANCE: Suturing the hamstring tendon graft in a whipstitch fashion is recommended for the femoral cross-pin fixation of an anterior cruciate ligament graft.
机译:目的:确定是否要用鞭打缝合法缝合软组织移植物是必不可少的步骤,以确保交叉销钉固定技术在前交叉韧带重建中具有足够的初始固定强度。方法:将猪指伸肌腱用作四链软组织移植物。使用十字销固定技术(RigidFix; Ethicon,Norderstedt,德国)将标本固定在52个猪股骨隧道内。在第一组(n = 28)中,使用whipstitch技术缝合了移植物的环状部分。在第二组(n = 28)中,未缝合移植物。初始固定特性是使用单周期破坏载荷方案或动态载荷方案确定的,将移植物置于0度至90度之间的1,000次屈伸屈伸载荷循环中,然后进行最终破坏载荷。在未加载和动态加载的移植物中,组织形态学可视化了移植物-钉相互作用和移植物-隧道界面。结果:动态加载后,与未缝合的移植物相比,缝合的植入物的残余位移更低。与动态载荷后的缝合移植物相比,非缝合移植物的最终破坏载荷明显更低。组织形态学分析表明,动态载荷后未缝合的移植物在隧道内移位,而缝合的移植物仍保留在原位。如果交叉销未穿过筋环,则缝合的移植物可提供更高的固定强度和更少的移植物移位。结论:本研究结果表明,与使用股骨交叉销固定技术的非缝合移植物相比,缝合四联腱移植物的环状部分提供了优越的生物力学移植物固定特性。临床相关性:建议以鞭打方式缝合绳肌腱移植物,以用于前交叉韧带移植物的股骨交叉固定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号