首页> 外文期刊>Archives of Physical Medicine and Rehabilitation >A novel video game--based device for measuring stepping performance and fall risk in older people.
【24h】

A novel video game--based device for measuring stepping performance and fall risk in older people.

机译:一种新颖的基于视频游戏的设备,用于测量老年人的踩踏性能和跌倒风险。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: To determine whether a dance mat test of choice stepping reaction time (CSRT) is reliable and can detect differences in fall risk in older adults. DESIGN: Randomized order, crossover comparison. SETTING: Balance laboratory, medical research institute, and retirement village. PARTICIPANTS: Older (mean age, 78.87+/-5.90y; range, 65-90y) independent-living people (N=47) able to walk in place without assistance. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Reaction (RT), movement, and response times of dance pad--based stepping tests, Physiological Profile Assessment (PPA) score, Digit Symbol Substitution Test (DSST) score, time to complete the Trail Making Test (TMT) A+B, Fall Efficacy Scale International (FES-I) score, Activities-specific Balance Confidence (ABC) Scale score, and Incidental and Planned Exercise Questionnaire (IPEQ) incidental IPEQ activity subscore. RESULTS: Test-retest reliability of the dance mat CSRT response time was high (intraclass correlation coefficient model 3,k=.90; 95% confidence interval [CI], .82-.94; P<.001) and correlated highly with the existing laboratory-based measure (r=.86; 95% CI, .75-.92; P<.001). Concurrent validity was shown by significant correlations between response time and measures of fall risk (PPA: r=.42; 95% CI, .15-.63; P<.01; TMT A: r=.61; 95% CI, .39-.77; TMT B: r=.55; 95% CI, .31-.72; DSST: r=-.53; 95% CI, -.71 to -.28; P<.001; FES-I: Spearman rho=.50; 95% CI, .25-.69; ABC Scale: Spearman rho=-.58; 95% CI, -.74 to -.35; P<.01). Participants with moderate/high fall-risk scores (PPA score >1) had significantly slower response times than people with low/mild fall-risk scores (PPA score <1) at 1146+/-182 and 1010+/-132ms, respectively (P=.005), and multiple fallers and singleonfallers showed significant differences in RT (883+/-137 vs 770+/-100ms; P=.009) and response time (1180+/-195 vs 1031+/-145ms; P=0.017). CONCLUSIONS: The new dance mat device is a valid and reliable tool for assessing stepping ability and fall risk in older community-dwelling people. Because it is highly portable, it can be used in clinic settings and the homes of older people as both an assessment and training device.
机译:目的:确定选择的踏步反应时间(CSRT)跳舞毯测试是否可靠,并且可以检测出老年人跌倒风险的差异。设计:随机顺序,交叉比较。地点:平衡实验室,医学研究所和退休村。参与者:年龄较大(平均年龄:78.87 +/- 5.90y;范围:65-90y)的独立生活者(N = 47)能够在没有帮助的情况下就地行走。干预措施:不适用。主要观察指标:基于跳舞垫的踩踏测试的反应(RT),运动和响应时间,生理曲线评估(PPA)得分,数字符号替代测试(DSST)得分,完成轨迹制作测试(TMT)的时间A + B,国际秋季效能量表(FES-I)得分,活动特定的平衡信心(ABC)量表得分以及偶然性和计划锻炼问卷(IPEQ)偶然性IPEQ活动评分。结果:舞垫CSRT响应时间的重测信度较高(类内相关系数模型3,k = .90; 95%置信区间[CI] ,. 82-.94; P <.001),并且与现有的基于实验室的指标(r = .86; 95%CI,.75-.92; P <.001)。并发有效性通过响应时间与跌倒风险度量之间的显着相关性显示(PPA:r = .42; 95%CI,.15-.63; P <.01; TMT A:r = .61; 95%CI, .39-.77; TMT B:r = .55; 95%CI,.31-.72; DSST:r =-。53; 95%CI,-。71至-.28; P <.001; FES -I:Spearman rho = .50; 95%CI,.25-.69; ABC比例:Spearman rho =-。58; 95%CI,-。74至-.35; P <.01)。跌落风险得分为中/高(PPA得分> 1)的参与者的响应时间明显慢于跌倒风险得分为低/中度(PPA得分<1)的参与者,分别为1146 +/- 182ms和1010 +/- 132ms (P = .005),而多个跌落者和单跌倒者/非跌倒者在RT(883 +/- 137 vs 770 +/- 100ms; P = .009)和响应时间(1180 +/- 195 vs 1031 + / -145ms; P = 0.017)。结论:新的跳舞毯设备是评估老年人社区居民踩踏能力和跌倒风险的有效且可靠的工具。由于它具有高度的便携性,因此可以在诊所和老年人的家中用作评估和培训设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号